background image

All-in-one Convenience

Cold, Ambient and Hot Water Dispenser with UV

REN- HCA2200

Operation Manual

Operation  and  Setting

11- 15

Installation

1

Page

10

8, 9

5

3

2

Replacement  of  UV

Cleaning  

  Maintenance

Safety  Reminder

Directions  for  Use

Preface / Parts

Contents

Operation  Method

4

Replacement  of  Filter

6, 7

Please read these instructions completely before operating this unit

Ver2_10092018

Содержание Renaissance REN- HCA2200

Страница 1: ...Manual Operation and Setting 11 15 Installation 1 Page 10 8 9 5 3 2 Replacement of UV Cleaning Maintenance Safety Reminder Directions for Use Preface Parts Contents Operation Method 4 Replacement of Filter 6 7 Please read these instructions completely before operating this unit Ver2_10092018 ...

Страница 2: ...de Safety Lock IC Board Control Panel Ambient Water Button Cold Water Button Preface Parts Before using this water dispenser we advise you to read this manual thoroughly Please follow the instructions to ensure proper operation and the lasting of the dispenser ...

Страница 3: ... 1 4 PE water pipe between inlet ball valve and inlet connector See drawing B 1 4 Inlet Ball Valve 1 4 PE Water Pipe 1 4 Inlet Ball Valve Water In Connector Inlet Water Pressure Minimum 10Psi 68 947 Pa Maximum 40Psi 275 790 Pa Connecting divertor to ourside threads on faucet Remove Existing Aerator Swivel Collar Gasket Adapter Gasket Adapter Swivel Collar Handle Handle Faucet adapters use size as ...

Страница 4: ... for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person resposible for their safety 2 Children should be supervised to ensure that they do not play with the appliance 3 This appliance is intended to be used in household and simil...

Страница 5: ...use Now wait for 2 to 3 minutes for the tanks to be refilled this should be an automatic process as long as the water supply is switched on at the faucet or under sink permanently If not manually turn on the supply to allow water flow When the tanks are filled the dispenser is ready to for heating and chilling 2 Turn ON the power switches on the back of the dispenser Indications relating to the ho...

Страница 6: ...h to indicate malfunction To replace UV Lamp please disconnect the machine from the electricity before starting any procedures First press the button as directed in 1 to open the top cover Second follow steps 2 3 and 4 to remove the UV cover Then take out the used damaged UV Lamp and replace with a new one to complete the replacement 5 ...

Страница 7: ...e WARN sign will flash to indicate filters need to be changed To replace filters please turn off the dispenser from the electricity before starting any procedures First press the button from behind the unit as directed in order to open the top cover Second follow steps 2 3 and 4 to remove the filters Then replace with a set of new filters to complete the replacement F1 F2 6 ...

Страница 8: ...sition Then you need to reset the day counter and flow meter back to 0000 Hold the safety lock button and Set switch for 3 seconds until you hear 5 beep sounds Safety Lock Set Switch Once the filter counter already reset you MUST do flushing the new filter for at least 1 2L by pressing Ambient water button continuously Ambient Water Button 7 ...

Страница 9: ...ll be shown on the display Please place the drip tray back and press the drip collector to let it to pop out shown by arrow A Take out the drip collector and empty the water inside shown by arrow B Place it back and the dispenser will provide water again 2 When the drip collector is full water will not come out when pressing the water buttons 8 ...

Страница 10: ...e cleaning 2 Remove the caps on top of the hot water and cold water drains The remaining water in the tanks will drain out Cleaning may start when both tanks are emptied Please put the caps back when cleaning is done Caution For your safety please contact your distributor or qualified technician for repairment when the water dispenser is damaged 9 ...

Страница 11: ...t may provide water to containers of all sizes When filling a small container or cup simply open the drip tray as shown If the container is taller or bigger please keep the drip tray and fill it directly under the dispensing point as shown 10 ...

Страница 12: ...ar flashes Cold water in use The 5o C next to it is the cold water temperature When chilling the water the color bar flashes UV in use Flow Meter Showing liters of water produced F 1500 L stands for 1500 liters have been produced Day Counter Showing how long the filters were used F 0180 Day means the filters were used for 180 days Energy saving in use Soda in use If no hot water soda and its tempe...

Страница 13: ...t saves the setting automatically after 30 seconds SET Safety Lock To adjust cold water temperature press set 2 times to indicate current cold water temperature Press set again and hold for 3 seconds the temperature may be changed from 2 to 8o C Default setting is 2 To adjust surrounding brightness press set 3 times to indicate current brightness level Press the internal switch and hold for 3 seco...

Страница 14: ...an the current setting level the heating system will activate after 1 minute Press the lock button Within 5 seconds press Set to activate reboil A short beep sound will be heard and the hot water color bar on the screen flashes as to indicate heating in process When reboil starts it will not stop till water reaches 100o C To stop heating press lock and then press set 6 Reset Day Counter and Flow M...

Страница 15: ...r over 40 seconds or buttons jammed Remove button jam to return to normal status Drip collector is full over 3 seconds Drain the collector to return to normal status C101 C102 C103 C201 C202 C203 C301 C302 C303 OFF FULL 8 Alarm and Malfunctions When C101 to C302 appears chilling and heating systems are both off When C101 to C202 appears water may still be provided The unit will make short beeping ...

Страница 16: ...ignal will appear as 203 on the display for safety concern 5 When the fan is damaged burnt off short circuit or disconnected alarm signal 203 will appear Please be aware that when unable to dissipate heat will cause damages to the compressor 6 IC board and the fan will perform self testing when each time the unit is on 7 Fan control wiring improved The power lowers automatically from 33V to 24V to...

Отзывы: