Water Level Switch WPS 3000plus |
15
LEDS:
1.
LED
“
SENSOR MIN
”
ON:
The liquid has reached the level of Sensor
“
MIN
;”
2.
LED
“
SENSOR MAX
”
ON:
The liquid has reached the level of Sensor
“
MAX
;”
3.
LED
“
FEHLER
”
(ERROR) ON:
The precondition is a water contact of the water sensors! For example,
the water sensors are reversed and the water sensor 1
“
sensor MIN
”
is
interrupted or not connected.
4.
LED
“
REL. EIN
”
ON:
The relay is switched
“
ON
”
MODE-SWITCH:
1.
POSITION
“
NACHFÜLLEN
”
(refill):
The device has been configured into refill mode.
2.
POSITION
“
ENTLEEREN
”
(empty):
The device has been configured to empty/discharge liquid level/tank
The device can be configured to either refill a tank of liquid or to discharge/
empty the liquid level. The two drawings on page 21 show the operating princi-
ple of the WPS 3000plus.
TECHNICAL DATA
–
Power supply: 230 V/50
–
60 Hz
–
Power consumption: max. 1,5 W
–
Switching power: max. 3000 W
–
Sensitivity: < 50 kOhm
–
Class: IP 20
–
Sensor connection: RJ 45 socket
–
LED indicators : Power, Sensor Min,
Sensor Max, Error und Rel. On
–
Package contents: 2 water sensors each
with 10 m cable and RJ 45 plug