EXTERNAL CONTROL
185
PEL-3000(H)
External
relay driver
20
19
NO
J1
connector
Input
Terminals
NO
Note
The external relay driver is not a standard accessory.
Please provide your own external relay and driver
circuit.
Monitor Signal Output
Trigger Signal Output
Description
The trigger output signal is generated every time a
switching operation is performed (i.e., Dynamic
mode) or when a Fast or Normal Sequence is
executed and the TRIG OUT parameter is enabled.
The trigger output signal from TRIG OUT BNC is a
5V pulse of at least 2us with an impedance of
500Ω. The common potential is connected to the
chassis potential. The signal threshold level is TTL.
Time
amplitude
TRIG OUT = ON
TRIG OUT
Start of step
or switch
operation
Содержание PEL-3000 Series
Страница 1: ...DC Electronic Load PEL 3000 H Series USER MANUAL VERSION 2 00 ISO 9001 CERTIFIED MANUFACTURER ...
Страница 24: ...PEL 3000 H User Manual 22 PEL 3111H PEL 3211 Booster Pack PEL 3211H Booster Pack ...
Страница 29: ...GETTING STARTED 27 GRA 413 JIS standard 149 532 5 482 6 GRA 414 E EIA standard 132 382 5 477 6 ...
Страница 41: ...GETTING STARTED 39 Fasteners 2 ...
Страница 207: ...REMOTE CONTROL 205 6 7 8 9 The function check is complete ...
Страница 209: ...FAQ 207 For more information contact your local dealer or GWInstek at www gwinstek com marketing goodwill com ...
Страница 229: ...APPENDIX 227 Operating Area PEL 3021 ...
Страница 230: ...PEL 3000 H User Manual 228 PEL 3041 ...
Страница 231: ...APPENDIX 229 PEL 3111 ...
Страница 232: ...PEL 3000 H User Manual 230 PEL 3211 Booster Pack PEL 3021H ...
Страница 233: ...APPENDIX 231 PEL 3041H ...
Страница 234: ...PEL 3000 H User Manual 232 PEL 3111H PEL 3211H Booster Pack ...
Страница 235: ...APPENDIX 233 ...