COMMAND SYNTAX
284
Example
:SOURce2:TTL4:BSTate?
Command
:SOURce2:BSIZe <n>
Function
This Command sets the Digital I/O bit size to 3 or 4.
In the 3-bit mode, Digital I/O line 4 becomes EOT,
/EOT, BUSY, or /BUSY based on the
SOUR2:TTL4:MODE and SOUR2:TTL4:BST
Commands above. In 4-bit mode, Digital I/O line 4 is
controlled manually if SOUR2:TTL4:MODE is set to
EOT. If SOUR2:TTL4:MODE is set to BUSY,
operation is identical to the 3-bit mode.
<n> = 3 Set 3-bit size
4 Set 4-bit size
Example
:SOURce2:BSIZe 3
Command
:SOURce2:BSIZe?
Function
Query Digital I/O port bit size
Example
:SOURce2:BSIZe?
Command
:SOURce2:CLEar[:IMMediate]
Function
This action Command is used to immediately restore
the digital output lines to the output pattern defined
by the :TTL:LEVel Command.
Example
:SOURce2:CLEar
Command
:SOURce2:CLEar:AUTO <b>
Function
This Command is used to enable or disable auto-clear
for the digital output lines. When enabled, the output
pattern will clear automatically after the “pass or fail”
output bit pattern of a limit test is sent to a handler
via the digital output lines. The :DELay Command
specifies the pulse width of the limit test bit pattern.