ASR-3000 Series User Manual
82
Setting the Peak Current Limit
Background
Setting the peak current limit sets a limit on the
current that can be sourced by the power supply.
Once the output current over the setting, the
output will set to off.
Note
When the peak current limit is tripped, an alarm will
sound. Press
Shift + Cancel
to clear the Ipk alarm.
Steps
1.
Press
Shift + Irms
to access the IPK
Limit menu.
+
2.
Use the scroll wheel to toggle between IPK+
(upper) and IPK- (lower) settings followed by
pressing
Enter
to get into parameter, respectively.
IPK+
IPK-