APS-7000 Series User Manual
130
Sequence Settings
Entering the
Sequence Menu
1.
Press
Test
.
Test
2.
Press
Mode[F1]
and use the scroll wheel to
display
Sequence
Mode
and then press
Enter
.
Sequence Mode
F1 MODE
Voltage range
Steps
3.
Use the scroll wheel to go to the
Step
setting
and press
Enter
.
4.
Use the scroll wheel to select the step number.
0 is always the starting step for the sequence.
Step
0 ~ 255
5.
Go to the
Time setting
and set the duration of
the step.
Time
0.01 ~ 999.99s
6.
Go to the
Jump To
setting and choose which
step to jump to, or turn the setting off.
Step
ON, OFF, 0 ~ 255
7.
Go to the
Jump Cnt
setting and set the number
of times the current step will loop.
Содержание APS-7000 Series
Страница 1: ...Programmable AC Power Source APS 7000 Series USER MANUAL ISO 9001 CERTIFIED MANUFACTURER ...
Страница 25: ...GETTING STARTED 25 Indicates that the panel lock is active ARB Indicates that the ARB function is active ...
Страница 89: ...OPERATION 89 Exit 4 Press Exit F4 to exit from the MISC Configuration settings Example Settings ...
Страница 111: ...OPERATION 111 Simulate Example ...
Страница 157: ...COMMUNICATION INTERFACE 157 Exit 6 Press Exit F4 to exit from the serial port settings ...
Страница 187: ...APPENDIX 187 APS 7000 Dimensions APS 7050 402 545 5 430 110 4 87 9 Scale mm ...
Страница 188: ...APS 7000 Series User Manual 188 APS 7100 561 6 705 5 430 110 4 87 9 Scale mm ...
Страница 189: ...APPENDIX 189 APS 7200 402 5 310 5 429 8 682 4 649 2 Scale mm ...
Страница 190: ...APS 7000 Series User Manual 190 APS 7300 491 5 399 5 429 8 682 4 649 2 Scale mm ...