GVS Archimedes A1200 Скачать руководство пользователя страница 1

1

Weighing Platform

Frame

Nacelle

Scale

Water Bubble  

Level

GVS Archimedes

8.8.8.8.8.8

P S

G

Display: 

G

 

    Gold Mode 

S

  

    Silver Mode

P

 

    Platinum Mode

M1

      Weight in air

M2

      Weight in water

O

 

    Value is stable

Label:

 

S.C.

  Gold-Silver-Copper Alloy 

C.

 

Gold-Copper Alloy  

 

(e.g. Krugerrand)

S.

 

Gold-Silver Alloy 

SG

  Specific weight

Buttons:

ON/OFF

 

Turns device on/off

A

 Utility-button 

 

 

(switch through modes)

B

 

Confirmation-button

ENTER

 Save-button

ZERO

 

Back to zero

C

 Technician-button

Содержание Archimedes A1200

Страница 1: ... Platinum Mode M1 Weight in air M2 Weight in water O Value is stable Label S C Gold Silver Copper Alloy C Gold Copper Alloy e g Krugerrand S Gold Silver Alloy SG Specific weight Buttons ON OFF Turns device on off A Utility button switch through modes B Confirmation button ENTER Save button ZERO Back to zero C Technician button ...

Страница 2: ...s During this time the electric circuits will stabilize IMPORTANT for calibration 3 Press the button ZERO to return the device to 0 00 4 Press and hold ZERO until the display shows CAL 5 The scale is now in calibration mode and shows 500 00 6 Place the calibration weight at the center of the weighing platform 7 The GVS Archimedes will now be calibrated automatically 8 The calibration is finished w...

Страница 3: ... of the according alloy Press button A to switch between the alloys At first the carat value for gold silver copper will be displayed then gold copper e g Krugerrand and then for gold silver After this the specific gravity S G value will be displayed in g cm 7 Press ENTER again to show the percentage of gold of the according alloy Press A to switch between the alloys 8 By pressing ENTER again the ...

Страница 4: ... with paper towels and cleaning ethanol Avoid finger prints on the inside of the water tank Replace the distilled water regularly every 1 2 months The maximum capacity is 1 200 g Avoid overloading the GVS Archimedes Troubleshooting FAQs Why does the calibration not work Try longer warm up phase before calibration leave it turned on for 30 60 minutes My results differ from what I expect Temperature...

Страница 5: ...Pt 1000 21 45 21 45 Pt 950 20 04 20 64 Pt 900 18 80 19 88 Pt 850 17 71 19 18 Pt 800 16 73 18 53 Pt 750 15 86 17 92 Precious metals Specific weight g cm at 20 C Platinum 21 45 Gold 19 32 Rhodium 12 44 Palladium 12 02 Silver 10 53 Other metals Specific weight g cm at 20 C Ruthenium 12 41 Palladium 12 02 Lead 11 36 Copper 8 93 Nickel 8 90 Cobalt 8 85 Iron 7 87 Tin 7 30 Zinc 7 13 Titan 4 51 Aluminium ...

Отзывы: