Installation - Existing Construction
CAUTION:
Make sure the power is switched off at the service panel before starting
installation.
1
Removing the existing fan
□
Remove the old fan from the ceiling.
2
Measuring the ceiling opening
□
Measure the opening to ensure it is large enough to
accommodate the new fan body (A) (9.25 in. x 8.9 in.).
3
Enlarging the opening (optional)
□
If this fan is not replacing an old fan, cut a 9.25 in. x 8.9 in.
opening for the fan body (A).
□
MAKE SURE ONE EDGE OF THE OPENING IS FLUSH WITH
THE JOIST FOR INSTALLATION FROM BELOW.
9.25”
8.9”
4
Removing the motor and power line
□
Loosen the three screws where indicated by the arrows.
□
Remove the motor and power line (1) from the housing (A).
A
1