ZONESCAN INSTALL User Manual page
–
23
5.1.6
Adding Measurement Point
A measurement point usually consists of a Repeater and a Logger. The workflow supports both ways
–
installing the logger first, or installing the repeater first and will adapt automatically depending on
which device is first scanned.
Also adding multiple Loggers to one Repeater is supported, though it should be carefully checked, as
this option might result in weak radio communication links, which would lead to loss of data. When in
doubt, add another Repeater.
5.1.7
Connection Test
The most important part of the adding measurement point workflow is the connection test
–
make
sure you get the best possible radio connection for your devices. This will influence reliability as well
as battery life.