Gusher MSCJ4 SERIES Скачать руководство пользователя страница 1

in

st

ru

ct

io

m

an

ua

l

in

st

ru

ct

io

m

an

ua

l

MSCJ4

AND

MSCJ4-19A

SERIES

GUSHER PUMPS, INC.

115 INDUSTRIAL DRIVE

WILLIAMSTOWN, KY 41097

PHONE: 859-824-3100

FAX: 859-824-7428

www.gusher.com

MAINTENANCE  •  INSTALLATION  •  OPERATIONS

Содержание MSCJ4 SERIES

Страница 1: ...uction manual instruction manual MSCJ4 AND MSCJ4 19A SERIES GUSHER PUMPS INC 115 INDUSTRIAL DRIVE WILLIAMSTOWN KY 41097 PHONE 859 824 3100 FAX 859 824 7428 www gusher com MAINTENANCE INSTALLATION OPERATIONS ...

Страница 2: ...S 4 NAMEPLATE INFORMATION 5 RECEIVING INSPECTION 5 OPERATION MAINTENANCE 6 PARTS LIST 7 MSCJ4 STANDARD DUTY DRAWING 8 MSCJ4 19A STANDARD DUTY DRAWING 9 MSCJ4 19A HOSTILE DUTY DRAWING 10 TROUBLE SHOOTING 11 DISASSEMBLY PROCEDURE 12 ...

Страница 3: ...ing to make connection with a pump Use only fasteners of proper size and mate rial Ensure there are no missing fasteners Beware of corroded or loose fasteners OPERATION Do not operate below minimum rated flow or with suction discharge valves closed Do not open vent or drain valves or remove plugs while the system is pressurized MAINTENANCE SAFETY Always lockout power Ensure pump is isolated from t...

Страница 4: ...er Pumps Inc will replace or repair within one year of shipment from our plant any pump in our judgment that has failed due to defects in materials or workmanship provided the pump has been properly installed and maintained and has not been subject to abuse These pumps must return to Gusher Pumps Inc with complete history of service for inspection and warranty consideration Gusher Pumps Inc does n...

Страница 5: ...ump without proper prime sufficient liquid in pump casing WARNING Personal injury will result if procedures outlined in this manual are not followed NEVER operate pump below recommended minimum flow or when dry ALWAYS lock out power to the motor before performing pump maintenance NEVER operate pump without safety devic es installed NEVER operate pump with discharge valve closed NEVER operate pump ...

Страница 6: ...nd that you check the model number horsepower current characteristics and ft head of pump received to ensure that you have received the pump you ordered for your specific operating conditions If you should find some discrepancy report it to Gusher at once If your pump is not going to be installed within six months several precautions must be tak en 1 Preservative treatment of bearings and ma chine...

Страница 7: ...y in clean liquid with SG of 1 the pump requires very little attention Before shipment all Gusher pumps have been tested and greased at the plant therefore lubri cation is not necessary for approximately six to eight months Remember when lubricating ball bearings that too much grease will cause bear ings to run hot so grease bearings sparingly when it is necessary We recommend the use of Chevron S...

Страница 8: ... Low Pressure 1 9 65030 Wear Ring 1 10 62126 1 C Bushing 1 11 63125 1 CRS Spacer Sleeve 1 12 P27125 OR CI Volute High Pressure Varies 13 Varies Shaft 1 MSCJ4 19A SERIES Hostile Duty Configuration Parts List 1 Varies Motor 1 2 P42133 2 19A Body 1 3 84138 Mechanical Seal 1 4 P25125 1 4 0 CI Impeller High Pressure 1 5 62060 1 Bushing 1 6 P25125 4 0 CI Impeller High Pressure Varies 7 59126 2 CI Adapte...

Страница 9: ...8 ...

Страница 10: ...9 ...

Страница 11: ...10 ...

Страница 12: ... too small Foot valve is too small Foot valve or suction opening not sub merged deep enough Vibration Bent shaft Pipe strain Impeller clogged Coupling alignment off Not enough pressure Speed too low Air in water Mechanical defects Wear ring is worn Impeller damaged Impeller diameter too small Pump works for a while then loses suction Leaky suction line Water seal plugged Impeller clogged Air or ga...

Страница 13: ...or can 18 and pry the motor end bell 19 off of the motor can 18 14 Remove the motor can 18 from the motor can adapter 16 if applicable 15 Once you have removed the motor can 18 then remove the motor can adapter bolts 2 and the motor can adapter 16 if applicable to your pump 16 Remove the lower bearing retainer bolts 3 17 The use of a hand press is recommended in pressing the shaft 17 out of the pu...

Страница 14: ...of California 8226 Salt Lake Avenue Cudahy CA 90201 Phone 323 773 0847 Fax 323 773 0958 Email www gusherca aol com Gusher Pumps of New Castle 403 North Ninth Street New Castle IN 47362 Phone 765 529 5624 Fax 765 521 0008 Email www gusherpump insightbb com BSM Pump Corp 180 Frenchtown Road North Kingstown RI 02852 Phone 401 471 6350 Fax 401 471 6370 Web www bsmpump com Nagle Pumps 1249 Center Avenu...

Отзывы: