Central Module » Expanding the KVM matrix system by cascading
G&D DVICenter DP64 ·
18
Expanding the KVM matrix system by
cascading
Cascading increases the number of connectable target modules to up to 3,969.
To cascade your devices, connect a slave central module to the
Dynamic Ports
of a
master central module. The port must be configured for the connection of target
modules.
You can connect target modules or other slave central modules to the slave central
module (up to 2 cascade levels).
Maximum number of connectable computers
The following tables show the maximum number of computers subject to the num-
ber of consoles to be implemented.
In the
first cascade level
, you can increase the number of computers as follows
:
Consoles
Computers Central modules
Consoles
Computers Central modules
1
3,969
64
17
107
3
2
1,922
32
18
102
3
3
1,221
21
19
97
3
4
900
16
20
92
3
5
653
12
21
87
3
6
526
10
22
62
2
7
457
9
23
59
2
8
392
8
24
56
2
9
331
7
25
53
2
10
274
6
26
50
2
11
221
5
27
47
2
12
212
5
28
44
2
13
165
4
29
41
2
14
158
4
30
38
2
15
151
4
31
35
2
16
144
4
32
-
-