BIOSTAR

   12 / 15 / 23 kW 

 

Planing and Installation 

BS-01

 

 

 

 
 
 
 
 
 
 

EN-B31-003-V10-0515

 

 

Содержание BIOSTAR 12

Страница 1: ...Pelletfirung englisch BIOSTAR 12 15 23 kW Planing and Installation BS 01 EN B31 003 V10 0515...

Страница 2: ...ved GUNTAMATIC Heiztechnik GmbH Bruck 7 A 4722 PEUERBACH Tel 0043 0 7276 2441 0 Fax 0043 0 7276 3031 Email office guntamatic com It is important that you pay particular attention to the safety issues...

Страница 3: ...ngcirculation rule 15 3 CONSTRUCTION 16 3 1 Delivery 16 3 2 Carrying to installaion site 16 3 3 Positioning and aligning the boiler 16 3 4 Hydraulic Integration 17 3 5 Filling and bleeding the system...

Страница 4: ...turer may be fitted to the system 1 3 COMISSIONING Commissioning of the boiler must be carried out by an authorised GUNTAMATIC specialist or other qualified persons They will check whether the system...

Страница 5: ...ical Directive on Preventative Fire Safety pr TRVB H118 Germany Standard boiler regulations M FeuVO Hessen and Saarland in these states 16 FeuVO Hessen applies Switzerland Fire safety regulations www...

Страница 6: ...oiler room a fireproof collar must be fitted to the extraction and air return pipes at their wall exit points from the boiler room If the outfeed auger goes directly into the boiler room it is factory...

Страница 7: ...st 200 cm and must not be sealable With combustion boiler systems with a fuel heat output upwards of 50 kW the net clear cross sectional area must be increased to at least 5 cm per kW rated output acc...

Страница 8: ...m under the flue please follow the local laws D installation variant energy saving damper with explosion damper in the flue ca 50 cm under the flue please follow the local laws E flue wet non sensitiv...

Страница 9: ...height The minimum flue height is 5 10 m depending on boiler output The flue must terminate at least 0 5 m above the highest part of the building In the case of flat rooves the flue must terminate at...

Страница 10: ...in the flue approx 0 5 m below the point where the flue connecting pipe joins or alternatively in the flue connecting pipe close to its junction with the flue Flue draught setting Adjusting the flue...

Страница 11: ...vered in an pump truck The storeroom ort he filling conections has to be ordered that they are reachable form a tube which has a maximum length from 30 m On the second filling connection the Transport...

Страница 12: ...m minimum 40 cm and must be higher then a lenghth from 2 me but minimum 60 cm INFO The whole ventilation shift from 2 caps from our filling sets is 60 cm Over 30 t storage volume the requirements a co...

Страница 13: ...hine with Flex fuel supply with annother building section The maximal length of extracting screw amounts 3 m The maximal suction length is 25 m Minimum 2 fire security wristbands needed please respect...

Страница 14: ...ecurity wristbands needed please respect the minimum fire security rules Example 6 Construction with outside location of Box with textil tank Construct the outside locatiob of box with an textlil tank...

Страница 15: ...d model set MK261 Following funtions could be active Heatingcircle WW warmwater memory Heatingcircle 0 optional pumpingheatingcircle 1 third mixed heatingcircle Heatingcircle 1 optional pumpingheating...

Страница 16: ...boiler BS 01 Keep to the minimum wall clearances specified by the system planner and manufacturer If important details are missing please refer to the planning documentation or ask our Technical Supp...

Страница 17: ...hich turns quickly off A buffermemory is just usefull when it s operated with a Solar panel or a solid fuel boiler That in the programme attituted programme OFF the freeze function could be maded sure...

Страница 18: ...ded cost effenciently Either old pipes could be meant Expansion vessel The boiler operates in a sealed heating system and must be provided with an expansion vessel for pressure compensation To calcula...

Страница 19: ...it s the best opportunity to clean magnetit and rust sludge from the pipe system Filling the system Match the pressure of the system when cold to the air charge pressure of the expansion vessel Check...

Страница 20: ...ing pipe must rise upwards from the boiler to the flue at an angle of at least 6 and be connected with gas tight joints An inspection cover must be provided for cleaning the flue connecting pipe A Flu...

Страница 21: ...rews are screwed through without impact on the inside At the end of discharge screw the flange 4 Sketch 2 screw with bearings 3 Slacke the worm screw 5 Sketch 2 in the store room up to the block in th...

Страница 22: ...he propolsive unit 1 Check the tightness on the first suction operator Leakage could lead to filling fails 3 Don t lead suction pipes into the outside area or cold rooms because of consendation If no...

Страница 23: ...standind wood C If thhe distance would be bigger than 1 5 between the screw and the wall you have to install additional supporting beams F 4 You have to serrate 3 cm long strong woods or laminated rec...

Страница 24: ...filling noozels have to be grounded 1 5 mm access door It is a T30 EI230 C fire door or install hatch which opens from the inside out On the inside the manhole must be provided with a minimum of 3 cm...

Страница 25: ...ction of fabric tank occours with a seperated construction instruction Suction pipe For construction use the same introduction as you could find in the chapter system Flex Please attend the chapter fi...

Страница 26: ...he drop shaft flange 4 so donned that the centering bolt lock 5 and the bonded seal is not damaged 5 Remove the container screw 2 again so far that these can easily be supported on the ground The Cont...

Страница 27: ...uger casing and make sure it is making good contact firmly seated Temperature relief valves that are used as sprinkler systems must be tested and approved to DIN 3440 and guarantee a flow rate of at l...

Страница 28: ...e direction of arrow slightly forward and pull it downwards the platine with the connecting plug under accessible positions Mains power supply 230 VAC 50 Hz 13 A surge arrester recommend The mains pow...

Страница 29: ...have to prefer this kind of wiring The connection is rewire linear further cabling the CAN bus for example from the operating unit to the wall unit and the wall mounted unit to the remote unity wirrin...

Страница 30: ...AC TKS 1 firebox and ash box door switch 24VDC Stoker drive motor G1 230V AC Outfeed drive motor A1 230 VAC Outfeed blower A2 230 VAC Stoker sensor PT1000 Filling Sensor 12VDC Ignition fan 230V AC Bo...

Страница 31: ...qualified specialist The precondition is that the flue technician heating installer and electrician have cleared the system for operation The authorised GUNTAMATIC specialist will carry out the follow...

Страница 32: ...g board NORM M 7137 Requirements on the Pelletstorage at the private customer NORM M 7510 Guideline for the review from central heaters NORM H 5195 1 Austria Prevention from damage through nest and St...

Страница 33: ...n instructions 1 Firing BIOSTAR as price list 2 Flue draught regulator RE with Ex Klappe as price list 3 Outside temperature based controller MKR S30 031 4 GSM Module S15 002 5 Mixer valve positioner...

Страница 34: ...uctions 1 Firing BIOSTAR as price list 2 Flue draught regulator RE with Ex Klappe as price list 3 Regelung Set MKR S30 031 4 GSM Module S15 002 5 Mixer Stellmotor S50 501 6 Roomconstruction Roomstatio...

Страница 35: ...ng circulation could be operated room temperature leaded 1 Firing BIOSTAR as pricelist 2 Flue regulator RE with Ex Klappe as pricelist 3 Ruler Set MKR S30 031 4 GSM Module S15 002 5 Mixer Servermotor...

Страница 36: ...rature leaded 1 Firing BIOSTAR as Pricelist 2 Flue draft Regulator RE mit Ex Klappe as Pricelist 3 Rule Set MKR S30 031 4 GSM Module S15 002 5 Mixer Servermotor S50 501 6 Roomconstruction Roomstation...

Страница 37: ...perating pressure 30 max 3 30 max 3 30 max 3 Litre bar A Smokepipe B Flow C Backrun 130 1 1 130 1 1 130 1 1 mm Zoll Zoll Waterside Difference Difference 10K 1030 6 2 1285 13 5 1970 37 7 kg h mbar wate...

Страница 38: ...0 max 3 30 max 3 Litre bar A smokepipe B flow C backrun 130 1 1 130 1 1 130 1 1 mm Zoll Zoll water system resistance Difference 10K 1030 6 2 1285 13 5 1970 37 7 kg h mbar water system resistance Diffe...

Страница 39: ...2 2 m till 2 7 m FLEX 2 5 m off 2 7 m till 3 2 m FLEX 3 0 m off 3 2 m 3 7 m Length Storeroom inside Length Storeroom inside plus wall thickness 8 4 FEED SYSTEM BOX BS 01 Ma A B Ma C m Gewicht BOX 5 2...

Страница 40: ...40 GUNTAMATIC Heiztechnik GmbH A 4722 Peuerbach Bruck 7 Tel 0043 0 7276 2441 0 Fax 0043 0 7276 3031 Email office guntamatic com www guntamatic com Misprints and technichal Changes reserved...