Sensor Information Display - Error Messages
The Sensor Information Display shows the status of the sensor and its internal system throughout each period of operation.
Sensor Information Display Details
Below is a list of the messages that may appear if a problem occurs during operation, with descriptions of their meaning:
Display Screen Message
Description
Checking components
Checking the system components.
Reinstall Sensor IP:
xxx.xxx.xxx.xxx
The controller application has not been programmed (software is missing).
The remote installer can be used with the displayed IP address
CTRLBOOT Wtg cmd
V1.5.0.0
This message is displayed when the system begins booting.
Diagnostic exit
waiting for reboot
The system has exited the diagnostic mode and is waiting for the sensor to
reboot.
Download timed out
The link between the system and boot loader has failed.
Err writing sw event
There was an error writing a period software event to the system.
Failed
Programming failed.
Failed to init Receiver
The receiver failed to start correctly.
Failed to start rotor
The rotor motor could not be started.
Failed to suspend rotor
The rotor could not be suspended.
Going to running
Preparing to suspend the sensor.
Going to suspend
Preparing to suspend the sensor.
Low Temperature
Warming up system
The sensor’s temperature is currently below the normal operating
temperature and it has entered an automatic warm-up state. This state
prevents the rotor from turning until the system reaches a safe operating temperature.
-NN°C please wait...
The system is warming up and the temperature has reached NN degrees
°
C.
Power Fail
A low voltage supply has been detected.
Programming
CtrlApp Programming has been started.
Sensor
Information
Display