l
21
Client and DP Feed Connections - Serial Client, Serial DP
To Connect a Serial Sensor with Serial to the Client and Serial to the DP Feed:
Connect
Serial Port 0
to the
Client computer
and
Serial Port 1
to the
DP system
.
Configure the serial connections as shown below:
1 RX-
2 RX+
3 TX-
4 TX+
5 GND
6 Test
7 GND
8 +24V
DP
Feed
RS422 Link
to Vessel’s
DP System
Mains Power
85–264V AC
45–65Hz 45W
*
Serial 1
*
+24V output on pin 8 of both serial ports can be
used to power a 100mA data converter, if required.
Ferrite Bead
Ethernet 1
Ethernet 0
Serial 0
Serial 1
Power
Power LED
VFD Screen
Fuses
Stern
Bow
Service Connections
RS422 Link
9600 baud
8 bits
1 stop bit
No parity
1
2
3
4
5
6 7 8
9
1 RX-
2 RX+
3 TX-
4 TX+
5 GND
6 Test
7 GND
8 +24V
*
CyScan
Serial 0
Type 2 Marine
Processor
COM6
RS422 Link
38400 baud
8 bits
1 stop bit
No parity
RS422 Link
to Client
Computer
To Connect Cables to
Power/Serial Plugs:
.
.
Hook lever-tool into
slot above
connector-hole in
plug.
.
3
Whilst holding
down lever, insert
cable end into
connector-hole.
.
$
Release and remove
the lever-tool.
1
2
3
4
5
6 7 8
9
1 RX-
2 RX+
3 TX-
4 TX+
5 GND
6 Test
7 GND
8 +24V
*
CyScan
Serial 0
Hatteland
Panel PC
COM2
RS422 Link
38400 baud
8 bits
1 stop
bit
No
parity
1
2
3
4
5
6 7 8 9
1 RX-
2 RX+
3 TX-
4 TX+
5 GND
6 Test
7 GND
8 +24V
*
CyScan
Serial 0
Type 3 Marine
Processor
COM1..COM4
RS422 Link
38400 baud
8 bits
1 stop bit
No parity
Содержание CyScan
Страница 62: ......