DP Message Formats (Continued)
ASCII-17
Character
1
Range x 10000
2
Range x 1000
3
Range x 100
4
Range x 10
5
Range x 1
6
Range x 0.1
7 Space
8
Azimuth x 100
9
Azimuth x 10
10
Azimuth x 1
11
Azimuth x 0.1
12
Azimuth x 0.01
13
Azimuth x 0.001
14 Space
15
Ready (1 = data valid, 0 = data not valid)
16
Carriage Return (0x0Dh)
17
Line Feed (0x0Ah)
ASCII-22
Character
1
Range x 10000
2
Range x 1000
3
Range x 100
4
Range x 10
5
Range x 1
6
Range x 0.1
7 Space
8
Bearing x 100
9
Bearing x 10
10
Bearing x 1
11
Bearing x 0.1
12 Space
13
Azimuth x 100
14
Azimuth x 10
15
Azimuth x 1
16
Azimuth x 0.1
17
Azimuth x 0.01
18
Azimuth x 0.001
19
Space
20
Status (see below)
21
Carriage Return (0x0Dh)
22
Line Feed (0x0Ah)
Status: 0 = Range and/or azimuth not valid
1 = Range, azimuth and bearing valid
2 = Range and bearing valid if mobile station locked to a Mk IV beacon.
44