Configuration
3
Configuration
TCP/IP configuration by DHCP
After switching on the device is scanning on the Ethernet for a DHCP server and re-
quests an unused IP address. Check the IP address that has been assigned and ad-
just if necessary, that the same IP address is used at each restart. To turn off DHCP
use the software GBL_Conf.exe or use the configuration via the web interface.
To check the network settings with GBL_Conf.exe, start the program and choose
"All
Devices"
in the
"Search"
menu. From the list select the appropriate device. The lower
part of the left half of the window now shows the current network settings of the device.
If the IP address is displayed with the default settings (192.168.0.2), either no DHCP
server is present on the network, or there could be no free IP address assigned to it.
3.1
Output Ports
Choose Output Port to configure: This field is used to select the Output Ports to be
configured.
Label: You can assign a name up to 15 characters for each of the Output Ports. Using
the name, an identification of the the device connected to the port can be facilitated.
Start-up Monitoring
It is important, that if necessary the condition of the Output Ports can be restored after
a power failure. Therefore each port can be configured with Initialization status to a
specific start-up state. This start-up sequence can be carried out delayed by the para-
meter Initialization Delay. There is in any case a minimum one-second delay between
switching of ports.
Initialization status(coldstart): This is the port state (on, off, remember last state) the
port should be set when the device is turned on. The setting "remember last state"
saves the last manually set state of the Output Port in the EEPROM.
Initialization delay: Here can be configured how long the port should wait to switch to its
defined state after the device is turned on. The delay may last up to 8191 seconds.
This corresponds to a period of approx. two hours and 20 minutes. A value of zero
means that the initialization is off.
Содержание Expert Net Control 2304
Страница 1: ...Manual Expert Net Control 2304 2021 GUDE Systems GmbH Manual Ver 1 0 0 from Firmware Ver 1 0 ...
Страница 2: ...2 Expert Net Control 2304 2021 GUDE Systems GmbH ...
Страница 5: ...Device Description ...
Страница 12: ...12 Expert Net Control 2304 2021 GUDE Systems GmbH Device Description ...
Страница 13: ...Operating ...
Страница 23: ...Configuration ...
Страница 50: ...Specifications ...
Страница 81: ...Support ...
Страница 87: ...87 Expert Net Control 2304 2021 GUDE Systems GmbH Expert Net Control 2304 2021 GUDE Systems GmbH 11 18 2021 ...