CAUTION 

To prevent SERIOUS INJURY: 

- DO NOT connect power until instructed. 

- REINFORCEMENT is recommended for fiberglass, aluminum or lightweight steel garage doors BEFORE   

installing the door Bracket. Contact your door manufacturer for reinforcement options.

 

Fig.1 

Fig.2 

Fig.3 

Carton

 

Clevis Pin - 5/16” x 1-1/2” 

Hitch Pin

 

Self-Threading 
Screw - 1/4” x 5/8” 

 

UP 

Vertical Centerline of Door 

(a) (b) 

(c) 

2-4”  (5-10cm) 

Top E

dge o

f Doo

To Attach the Opener to the Header Bracket 

1. 

As shown in Fig.1, use the packaging carton as temporary 
support for the Opener. Place the Opener on carton to   
prevent damage.  

2. 

Align the mounting hole on the header rail to the mounting 
hole on the Header Bracket. 

3. 

Connect the Header Rail and the Door Bracket together 
with a 5/16” x 1-1/2” Clevis Pin and lock it in place with a 
Hitch Pin. 

To mount the Door Bracket 

Note

:  Some  door  reinforcement  kits  may  provide  direct           

attachment of the door arm to the reinforcement bracket. If you 
have a door reinforcement bracket with this option, skip this step 
and proceed with the next step “Mounting Opener to Ceiling”. 

1. 

Position the Door Bracket on the centerline of the door    
approximately 2” - 4” (5-10cm) below the top edge of the 
door, as shown in Fig.2. 

2. 

Depending on the construction of your door, install using 
one of the steps shown if Fig. 3 below: 

For  steel  /  lightweight  doors  with  vertical  steel            
reinforcements / factory reinforced. 

(a) Mark and drill two 3/16” holes.  Make sure not to drill 
through the garage door. Secure the Door Bracket with two 
1/4” x 5/8” Self-Threading Screws (provided) as shown in 
Fig.3(a). 

(b) Alternative installation: Drill two 5/16” holes through the 
door. Secure the Door Bracket using two 5/16” Bolts, lock 
washers and nuts (not provided) as shown in Fig.3(b). The 
length of bolts will depend on the thickness of your door. 

Wood door 

(c) Mark and drill two 5/16” holes through the garage door.  
Secure the Door Bracket using two 5/16” carriage bolts, 
washers and nuts (not provided) as shown in Fig.3(c). The 
length of bolts will depend on the thickness of your door. 

Note: DO NOT use Self-Threading Screws on a wood door. 

Attaching Rail to Header Bracket and Mounting Door Bracket 

Содержание DCS 3/4HP

Страница 1: ...ILL NOT CLOSE until the Photo Eye Safety System is properly installed and aligned REGULARLY CHECK and TEST the Opener according to the safety label to ENSURE SAFE OPERATION Retain this manual for futu...

Страница 2: ...3 Connecting Photo Eye Safety System 14 Connecting Wall Panel 15 Connecting Power 16 Adjustment Aligning the Photo Eye Safety System 16 Travel Limit Adjustment UP Limit 17 Travel Limit Adjustment DOWN...

Страница 3: ...ents x3 Hanging Brackets x 2 Self Threading Screw 1 4 x 5 8 Door Bracket Rail End Segment with Trolley Stop Bolt Clevis Pin Door arms 5 16 x 1 Clevis Pin Header Bracket 5 16 x 1 1 2 Pulley Trolley Sha...

Страница 4: ...ent SERIOUS INJURY or DEATH Before beginning installation of the Opener please complete the following test to ensure that your door is balanced and in good working condition A poorly balanced door can...

Страница 5: ...SERIOUS INJURY DO NOT connect power until instructed Keep hands and fingers clear from sprocket during operation Wear gloves when installing chain belt and cable Keep hands and fingers away from join...

Страница 6: ...heard when they are connected and locked as shown in Fig 3 To Link Cable with Chain Refer to Fig 4 Place the chain carton beside the rail hold the Chain to Cable Connector and pull about 8 20cm of ch...

Страница 7: ...Installing the Chain 1 Master Link Link Cap Spring Clip Cable Eyelet 2 Open end of chain Base of Rail 1 4 6mm Mid point of rail assembly Chain Top of Rail Actual Size x 1 THE SPROCKET COVER MUST BE SE...

Страница 8: ...ling as shown in Fig 3 Center the Header Bracket on the vertical mark no more than 6 15cm from the header wall Mark and drill holes to fasten the Header Bracket securely to a structural support Fig 1...

Страница 9: ...nt bracket with this option skip this step and proceed with the next step Mounting Opener to Ceiling 1 Position the Door Bracket on the centerline of the door approximately 2 4 5 10cm below the top ed...

Страница 10: ...ing Brackets to the structural supports using 5 16 x1 2 Lag Screws provided 7 Secure the Opener to the Hanging Brackets and secure each side with a 5 16 x 1 Bolt and Flange Nut provided 8 Move the doo...

Страница 11: ...1 Straight Door Arm Curved Door Arm Attaching Door Arms NOTE The trolley must be a minimum of 8 20cm away from the pulley To Connect Door Arm Follow the steps shown in Fig 1 1 Fasten the Straight Door...

Страница 12: ...To prevent SERIOUS INJURY or DEATH from a falling garage door In case of power failure or door obstruction PULL EMERGENCY HANDLE to release door from Opener When Emergency Release is in the released...

Страница 13: ...iped wire non polarized from the SAME accessory as shown in Fig 2 5 Check for proper connection by gently pulling on the wire The wire should not come out of the terminal NO exposed part of the wire s...

Страница 14: ...ernative Floor mounting 1 Place the Photo Eyes facing each other on each side of the garage door as shown in Fig 2 2 If attaching to concrete secure the photo eyes using concrete anchors and bolts not...

Страница 15: ...inside your garage To install the Wall Panel 1 Inside your garage install the back plate of the Wall Panel within sight of the door at a minimum height of 5 feet 1 5m off the ground Ensure it is insta...

Страница 16: ...The Photo Eye Safety System MUST be installed BEFORE connecting power The Photo Eye Safety System MUST be properly connected and aligned BEFORE operating the Opener Connecting Power For Permanent Wiri...

Страница 17: ...P DOWN FORCE LIMIT UP DOWN OK 1 2 3 4 About Travel Limit Adjustment Limit Adjustments regulate the fully open UP limit position and fully closed DOWN limit position at which the door will stop when op...

Страница 18: ...P DOWN FORCE LIMIT UP DOWN OK x2 UP DOWN FORCE LIMIT UP DOWN Travel Limit Adjustment II DOWN Limit x1 1 2 3 CAUTION WHILE PRESSING THE DOWN LIMIT BUTTON CAREFULLY WATCH DOOR TRAVEL DISTANCE RELEASE BU...

Страница 19: ...Force Auto Adjustment Following limit setting the unit is now ready to automatically adjust the forces for opening and closing the door Proceed with the following steps to complete adjustment 1 With...

Страница 20: ...the fully opened position 5 The Safety Reverse System works properly and the opener is ready to use If the door just stops on the object adjust the Opener as follows The close travel maybe inadequate...

Страница 21: ...keypad codes can be added to the unit by repeating the above procedures If more than 20 Transmitters are stored the first stored Transmitter will be replaced i e the 21st Transmitter replaces the 1st...

Страница 22: ...d in good working condition Emergency Release Knob Photo Eye Safety System Invisible Light Beam Actual Operating Scenario Wall Panel Operating the Opener Controls Operation Wall Panel Indoor Momentary...

Страница 23: ...ull to Disconnect Flip to reconnect Manual Operation Door status Activation using Wall Panel Transmitter Door at fully open close position Door will move to fully close open position Door is closing D...

Страница 24: ...oes not turn on Replace light bulb A19 incandescent Max 100W The courtesy light does not turn off Defective Logic Board The Opener hums as the Trolley hits the Trolley Stop Bolt in open travel 1 Make...

Страница 25: ...11 24908 Chain Item Part No Name Description 1 24919 Header Bracket 2 24917 Door Bracket 3 24925 Hardware Bag Installation hardware shown on P 3 4 24923 Curved Door Arm 5 24921 Straight Door Arm 6 24...

Страница 26: ...nsformer 3 Logic Board 4 Position Encoder 5 DC Motor 6 24981 Cover plate Front 7 24982 Cover plate Back 8 24980 Opener Cover 9 Lamp Plate 10 24905 Lamp Dome Should be replaced by qualified technician...

Страница 27: ...t itself ii To any additional damage or deterioration arising from attributable to the operation of the Operator after it is known to be defective 9 Exclusions to Warranty Period i Repair or Warranty...