background image

2m

1m

2m 3m

8m

15m

1m

2m

0

20m

Corridor-Plan View

2.3m

2m 3m

8m

15m

20m

Corridor-Side View

0

1m

1m

5m

10m

Curtain-Plan View

0

1m

Curtain-Side View

2.3m

1.2m

5m

10m

0

6m

8m

4m

4m

8m

0

2m 3m 5m

9m

12m

Volumetric-Plan View

Volumetric-Side View

2.3m

0

2m 3m 5m

9m

12m

Volumetric - Isometric View from above

Installation

Instructions

 Part No. 320531-0A

Apollo

15

Mounting
- The recommended mounting

height is 2.3 metres. This can
be raised or lowered if
required and the lens adjusted
to give optimum detection.

- Consider the area to be

protected and select the
appropriate lens type.
Volumetric lens supplied.
Although Apollo is designed to
tolerate a wide range of
environments, the normal
professional installation
guidelines should be
followed.

- Avoid the main false alarm

sources.
*Sunlight shining directly onto
 the detector.
*Strong air draughts onto the
 detector.

- Mount the detector on a stable

surface which is not subject to
vibration.

- Large objects placed in front of

the detector will cause
significant changes in
coverage.

Lens Declination Positions

A - Horizontal Main Beams
(normally used for pet alley with
fill in beams masked)
B - Normal Position
C - Full declination, detection
range about 50% at
recommended mounting height

Checking Detector Operation
- Switch on power and ensure

that the voltage at terminals 1
and 2 is between 8.5 and
16.5 V dc. A flashing LED will
show if the voltage is too low.

Walk Testing
- With the LED link fitted (as

supplied), walk test the area
checking that the LED lights
whenyou are in range,
indicating correct operation.

- Vertical adjustment

(approxi2

˚

, -12

˚ 

)

of the coverage pattern is
possible by loosening the lens
clamping screws and moving
the lens up or down until the
correct coverage is obtained.

- In corner mount installations,

horizontal adjustment
(approxi/-5

˚ 

) of the

coverage pattern can be
achieved by moving the base
sideways before tightening the
wall screws.

- Normal operation of 15 m

range, at a mounting height of
2.3 m, should have the lens
set to B.

LED Enable Link/Jumper
- This link (when fitted) enables

the walk test LED.

- If the walk test LED is not

required during normal
operation then remove and
park the LED enable link on
one pin.

- If the control panel provides an

LED control line, then this may
be connected to the detectors
LED Test Line for remote
operation.

- The LED can only be control

led remotely if the
LED link is removed and
parked on one pin.

Pulse Count Link
- The detector has been factory

set to pulse count. This is
recommended only for
volumetric applications and not
for curtain or corridor
applications.  Pulse count can
be disabled by fitting LK1.
When pulse count is selected,
the LED will flash on every
threshold crossing.

Final Installation Check
- Fit the front cover.
- Walk test the area checking

that alarms are indicated at the
control panel.

- If tamper is wired check

operation of tamper.

NOTE: Guardall recommend that
the detector is regularly walk
tested back to the control panel
and that installers advise their
customers to do this.

Alarm Memory (Apollo Elite
Only)
- Alarm memory means that

should an alarm occur when
the system is Set, then the
LED will not illuminate but the
alarm will be memorised by
the detector.  When the
system is subsequently Unset,
the LED will light constantly on
the detector that had  alarmed.
Reset occurs the next time the
system is Set.

For correct operation, the
Control Input must be wired
as follows:

Control Line

Mode

High

Set

Low or Open Circuit Unset

Note:  If alarm memory is not
required, then the Control Line
need not be wired. If the LED
Test Line is activated the
detector can be  walk tested
normally, without losing its
alarm memory.

20m

15m

20m

10m

10m

15m