9
Step 2
Make sure the control box power switch is in the
OFF
position. The ON/OFF Switch is located on the bottom of
the control box. Remove the control box cover and slide
the battery into position with its terminals to the
RIGHT
(
see illustration
). Connect the
BLACK
battery wire to the
NEGATIVE
(
–
) battery terminal. Connect the
RED
battery
wire to the
POSITIVE
(
+
) terminal.
Pay close attention to
the color of the wires. If the wires are connected incorrectly,
the control board will be damaged
.
NEVER
insert the
battery with the terminals to the left.
Mounting the Control Box
Step 3
Strip approximately 3/6" of insulation from each
wire of the power cable. Twist each exposed wire
tightly (there are seven [7] wires inside the power cable
sheath). Loosen sealing nut on strain relief hub at
bottom of control box. Insert power cable into control
box through strain relief. Thread approximately 6"
of the power cable into the control box and retighten
sealing nut until the power cable locks into place.
Step 1
Mount the control box using the screws (
provided
) or another
secure mounting method. The control box must be mounted at
least
3 feet above the ground
to protect it from rain splash,
snow, etc., and at least
3 feet from an AC power source to
prevent electrical interference
.
RED wire to POSITIVE (
+
) terminal
BLACK wire to NEGATIVE (
–
) terminal
RED
BLACK
25
FUSE
B
A
T
T+
B
A
T
T-
1 2
3
4
ON
DIP
S
TA
T
U
S
LE
A
R
N
R
M
T
R
E
C
E
IV
E
R
LE
A
R
N
M
A
S
T
L
IM
IT
LE
A
R
N
S
LV
L
IM
IT
S
3
S
4
A
LM
S
2
O
FF
S
O
FT
S
TA
R
T
O
FF
W
A
R
N
IN
G
O
FF
O
P
E
N
P
U
LL
S
LV
O
P
E
N
D
LY
.
M
O
D
E
1
O
FF
M
O
D
E
2
O
FF
O
N
O
N
P
U
S
H
S
IM
U
LT
.
O
N
O
N
1
2
0
M
IN
M
A
X
C
H
A
R
G
IN
G
P
W
R
I
N
GT
O RCVR
.
WHT
BLU
BRN
ORG
RED
BLK
GRN
WHT
BLU
BRN
ORG
RED
BLK
GRN
COM
GRN
BLK
RED
CYCLE
SAFETY
EXIT
SHADOW
OPEN
EDGE
COM
G
TO
T
R
A
N
S
F
LO
C
K
P
W
R
A
U
X
R
LY
P
O
W
ER
IN
P
U
T
S
C
O
N
T
R
O
L
O
U
T
P
U
T
S
M
A
S
T
E
R
C
A
B
LE
S
LA
V
E
C
A
B
LE
C
O
N
T
R
O
L I
N
P
U
T
S
A
U
TO
CL
OSE
TI
M
E
ST
A
LL
F
O
R
C
E
CLOSE
EDGE
18
V
A
C
or
SO
LA
R
GT
O
LO
C
K
A
U
X
Operator Power Cable
Strain Relief
Battery wires for
optional second battery.
12 Volt Battery
(included)
Space for optional
second 12 Volt battery
(see Accessory Catalog)
Sealing Nut
Hub
Lock Nut
Strain Relief
Use mounting
holes and screws
provided to mount
control box to a
secure surface.
25
FUSE
B
A
T
T+
B
A
T
T-
1 2
3
4
ON
DIP
S
TA
T
U
S
LE
A
R
N
R
M
T
R
E
C
E
IV
E
R
LE
A
R
N
M
A
S
T
L
IM
IT
LE
A
R
N
S
LV
LI
M
IT
S
3
S
4
A
LM
S
2
O
FF
S
O
FT
S
TA
R
T
O
FF
W
A
R
N
IN
G
O
FF
O
P
E
N
P
U
LL
S
LV
O
P
E
N
D
LY
.
M
O
D
E
1
O
FF
M
O
D
E
2
O
FF
O
N
O
N
P
U
S
H
S
IM
U
LT
.
O
N
O
N
1
2
0
M
IN
M
A
X
C
H
A
R
G
IN
G
P
W
R
I
N
GT
O R
CVR.
WHT
BLU
BRN
ORG
RED
BLK
GRN
WHT
BLU
BRN
ORG
RED
BLK
GRN
COM
GRN
BLK
RED
CYCLE
SAFETY
EXIT
SHADOW
OPEN
EDGE
COM
G
TO
T
R
A
N
S
F
LO
C
K
P
W
R
A
U
X
R
LY
P
O
W
E
R
IN
P
U
T
S
C
O
N
T
R
O
L
O
U
T
P
U
T
S
M
A
S
T
E
R
C
A
B
LE
S
LA
V
E
C
A
B
LE
C
O
N
T
R
O
L I
N
P
U
T
S
A
UT
O CL
OSE
TIME
ST
ALL FOR
CE
CLOSE
EDGE
18
V
A
C
or
SOL
AR
GT
O
LOCK
A
UX
1
2
3
4
5
6
7
NOTE:
The battery that came with your GTO/PRO®
SW2502,
MUST
be placed in the top (horizontal)
battery slot with the terminals on the
RIGHT
. The extra
(vertical) battery slot is for an optional second battery.
A second battery is recommended for solar and/or high
traffic applications, if needed.