LIMIT ADJUSTMENTS
TEST SWITCHES
CLOSE
STOP
OPEN
GTO Inc. Tallahassee, FL
SX4000 Logic Board Rev. E
MIN
MAX
MIN
MAX
OFF
120
<<< JOG >>>
SET
LIMIT
W1
CUT TO USE
3 BUTTON
STATION
CYCLE
SAFETY
OPEN EDGE
RUN 2
OPEN
CLOSE
STOP
COM
COM
COM
STALL FORCE ADJUST
LIMIT ADJUSTMENTS
TEST SWITCHES
MAX
OFF
120
<<< JOG >>>
<<< >>>
SET
LIMIT
AUTO CLOSE
TIMER
Setting the Limits
opeN liMit settiNg:
1.
Turn on operator power.
2.
Press and release the
opeN
button on the board and be prepared to press the
stop
button
when the gate reached the desired open position/limit.
3.
The
Jog
buttons can be used to bring the gate to the precise open position. The
Jog
buttons
will slowly run the gate when pressed and stop the gate when released.
4.
Once at the desired open position, press and hold the
set liMit
button for 3 seconds or until
the alarm sounds and
status leD
is on. At this time, release the
set liMit
button.
5.
Be prepared to stop the gate when it reaches the closed position.
closeD liMit settiNg:
1.
If not already closed, press and release the close button.
2.
Press and release the
close
button on the board and be prepared to press the
stop
button
when the gate reached the desired closed position/limit.
3.
The
Jog
buttons can be used to bring the gate to the precise closed position. The
Jog
buttons
will slowly run the gate when pressed and stop the gate when released.
4.
Once at the desired closed position, press and hold the
set liMit
button for 3 seconds or until
the alarm sounds and
status leD
is on. At this time, release the
set liMit
button.
5.
Open the gate to allow it to stop on its own.
6.
Open and close the gate to verify proper operations. If limits are not set
properly, redo limit setting steps above.
NOTE:
If limits are too short, use jog button to move arm short distances to stop gate at
the precise open or closed position.
CAUTION:
Be extremely careful not to stand in the path of the gate arm while setting limits.