background image

12

Installing the Post Bracket Assembly

The post bracket is designed to work on a 

flat

 fence post. Fence posts must be at least 6” square in order to mount the 

post bracket. 

NOTE:

 The best method of attaching the post bracket to metal 

post is welding. Round wood posts (no smaller than 8” diameter) 
may be notched to create a flat surface for attaching the post 
bracket. 

If bolts are used to mount the post bracket, the bolts must 

completely

 penetrate the fence post. If your fence post is wider 

than 8", it will be necessary to use carriage bolts longer than 
those supplied. On 

wood

 posts use a metal plate (not provided) 

between the nuts and post to prevent the operator from pulling 
the bolts and washers through the wood. 

On masonry columns use red heads or other secure masonary 
mounting hardware.

NOTE: 

A fence post smaller than 6" in diameter or 6" square 

should be made of metal instead of wood so that it will remain 
stable while the operator is moving the gate. 

Step 1:  

Close the gate and place your level against the 
horizontal cross member. The top of the level 
should be in the center of the cross member 
and should overlap the fence post. Scribe 
a line across the cross member and fence 
post. You will use this line to help determine 
position of gate and post brackets.

Recommended Reinforcement Examples

Installing Mounting Hardware

Содержание 4000XL

Страница 1: ...er agree to assume responsibility for all liability and use of this product releasing GTO Inc from any and all liability If you are not in agreement with this disclaimer or do not feel capable of prop...

Страница 2: ...ccess locations not servicing the general public in which unauthorized access is prevented via supervision by security personnel The GTO PRO 4000XL Gate Operator is intended for use with vehicular swi...

Страница 3: ...Mounting the Operator page 16 Installation of the Closed Position Stop page 16 Mounting the Control Box page 17 Connecting the Operator Power Cable page 18 Installing the Battery page 18 Powering the...

Страница 4: ...sory Catalog are available The GTO PRO 4000XL Operator features adjustable obstruction sensing This safety feature makes the gate stop and reverse direction within 2 seconds when it comes in contact w...

Страница 5: ...ns and warnings in this manual are identified with this warning symbol The symbol identifies conditions that can result in damage to the operator or its components serious injury or death Because GTO...

Страница 6: ...rator is proper for the type and size of gate its frequency of use and the proper class rating 2 Make sure the gate has been properly installed and swings freely in both directions Repair or replace a...

Страница 7: ...cess to it 2 Be careful with moving parts and avoid close proximity to areas where fingers or hands could be pinched 3 Devices such as contact sensors safety edges and non contact sensors photo beams...

Страница 8: ...ay to it at least once per month 7 Service the gate and gate operator regularly Grease hinges spray push pull tube with high quality silicone spray and replace the battery every 3 5 years 8 To operate...

Страница 9: ...ent The GTO PRO 4000XL utilizes Type A an inherent i e built in entrapment sensing system as the primary type of entrapment protection Also the GTO PRO 4000XL has provisions for the connection of Type...

Страница 10: ...peration and are required when installing the GTO PRO 4000XL Automatic Gate Operator Furthermore a walk through gate must be installed if pedestrian traffic is expected near the vehicular gate We reco...

Страница 11: ...rn control box power switch OFF 2 Disconnect front or rear mount from gate bracket 3 Pull operator away from front or real mounts DC SW 4000XL SERIES GTO Inc Tallahassee Florida USA Disconnect operato...

Страница 12: ...ENER Gate Bracket 1 Post Pivot Bracket 1 Post Bracket 1 Closed Position Stop Plate 1 Hairpin Clip 2 3 8 x 3 1 2 Clevis Pin 1 1 2 x 2 3 4 Bolt 2 3 8 x 3 3 4 Bolt 2 1 2 x 10 Carriage Bolt 2 8 Nylon Cabl...

Страница 13: ...talog The diameter of the fence post should be at least 8 round or 6 square in order to mount the post bracket see page 12 Depending upon the diameter of the fence post you may need longer carriage bo...

Страница 14: ...ing point arm stroke 22 max Minimum gate length is 8 ft Adjustable auto close timer 15 to 120 s and obstruction sensitivity Power terminal block accommodates a transformer or solar panels not both DIP...

Страница 15: ...on Overview Pull to Open Gates Gate Opens into the Property The diagram shown below is an example of a pull to open installation on a chain link fence and single gate Mounting the operator on a masonr...

Страница 16: ...d On wood posts use a metal plate not provided between the nuts and post to prevent the operator from pulling the bolts and washers through the wood On masonry columns use red heads or other secure ma...

Страница 17: ...ion the post bracket on the fence post with the mounting holes centered over the scribe line The post bracket should be flush with the edge of the fence post closest to the gate see illustration Mark...

Страница 18: ...rear mount bushing and post pivot brackets and secure with the clevis pin and hair pin clip Step 6 Place a small bushing under the the front mount and attach the gate bracket to the front mount using...

Страница 19: ...n t have 2 inches of clearance or the gate operator is binding on the post pivot bracket remove the bolt in the post bracket and readjust the pivot bracket until you can achieve the proper clearance W...

Страница 20: ...Remove hairpin clevis pin and washer from front mount and close the gate remember to support operator Fasten the closed position stop plate to the end of the gate frame on the gate centerline in line...

Страница 21: ...s stage of the installation the operator should be installed on the gate and the closed position stop should be in place Check List The gate is plumb level and swings smoothly on its hinges A plate or...

Страница 22: ...lock Terminal Block Terminal Block Wire Wire Connecting Operator Power Cable Sealing Nut Hub Lock Nut Strain Relief Step 1 Make sure the control box power switch is in the OFF position The ON OFF Swit...

Страница 23: ...ed All low voltage wire used with the GTO PRO Gate Opener must be 16 gauge dual conductor multi stranded direct burial wire see page 20 and the Accessory Catalog Do not run more than 1000 feet of wire...

Страница 24: ...less of color or polarity Tighten set screws against exposed end of wires A dab of household petroleum jelly on each terminal will help prevent corrosion ORG BLUE WHT GRN BRN RED MASTER INPUTS BLK SOL...

Страница 25: ...x to discourage insects from entering it and damaging the control board Step 6 Strip 1 2 of insulation from the ends of the low voltage wire Attach these stripped ends to the transformer terminals A d...

Страница 26: ...nd gate opener system DIP Switch 2 Warning Buzzer ON Buzzer warning enabled factory preset OFF Buzzer warning disabled The Warning Buzzer alerts you when the gate opener is beginning to either open or...

Страница 27: ...5 seconds Step 4 Press the transmitter button and allow the gate to return to the fully open position YOUR GATE S CLOSED POSITION LIMIT IS NOW PROGRAMMED TESTING YOUR CLOSED LIMIT SETTING Press your e...

Страница 28: ...e obstruction setting or Stall Force on the GTO PRO control board comes from the factory set at MIN minimum In many gate in stallations this setting will need to be adjusted to overcome the weight and...

Страница 29: ...attery and the DIP switches will be exposed To set a new code use a small screwdriver to move the switches All GTO transmitters are set to a standard code at the factory and are ready to operate your...

Страница 30: ...weather topography and external interference DO NOT mount upside down DO NOT mount on metal fence or post doing so will decrease signal range MOUNT so that you have line of sight between remote to an...

Страница 31: ...losing 4 EXIT OPEN Typically for use with exit loop or wand Activation of this input will open the gate if it s not already at the open position Activation of this input while at open limit will resta...

Страница 32: ...tector GTO PRO Push Button Control GTO PRO Automatic Gate Lock According to Application According to Application GTO PRO Vehicle Sensor Refer to Vehicle Sensor manual for additional connections Edge S...

Страница 33: ...position for the post pivot bracket insert the 5 16 x 1 3 4 bolt through the aligned holes of the post bracket and post pivot bracket and fasten it with the 5 16 washer and nut IMPORTANT If you loosen...

Страница 34: ...is OFF Use a small screwdriver to move the Number 4 DIP switch from the factory setting OFF Pull To Open to ON for Push To Open Turn power switch ON The control board is now configured to push the ga...

Страница 35: ...hen press and hold the LEARN MAST LIMIT button for 5 seconds This will clear the memory for the open limit position Follow steps one 1 to four 4 again Learn Master Limit Button 1 2 3 4 ON DIP STATUS L...

Страница 36: ...ad 1 beep then 2 beeps Master Motor Terminals Shorted Connections to Master Inputs Master Arm Power Cable Motor Circuit Board 1 beep then 3 beeps Slave Motor Terminals Shorted Connections to Master In...

Страница 37: ...mote If the remote works the problem is the accessory Status clear 6 blinks Open Edge Terminal Shorted Disconnect edge sensor photo beam or any other accessory wired to this terminal Try the remote If...

Страница 38: ...GTO Inc Technical Service Department is open Monday Friday 8 00 A M 7 00 P M Eastern Time Fax 850 575 8950 Web site www gtopro com Telephone 800 543 1236 Telephone 850 575 4144 PROFESSIONAL ACCESS SY...

Страница 39: ...e control box and date of purchase when calling for assistance 3 If repair or replacement of your gate operator is necessary the Service Department will assign a Return Goods Authorization RGA number...

Страница 40: ...recommended that you place a steel plate between the operator mounting brackets and masonry surface for additional strength B If a push to open installation is impossible due to traffic hazards terrai...

Страница 41: ...systems 12 Volt battery included Digital Keypad F310 The specially designed digital keypad can be easily installed as a wireless or wired keypad It can be programmed to use up to 25 different personal...

Страница 42: ...to 500 feet or hard wired up to 1000 feet Additional base stations available F3101MBC Replacement Battery RB500 Standard 12 volt 7 0 amp hour maintenance free battery for the GTO PRO 2500 GTO PRO 2000...

Отзывы: