background image

EN

Operating manual

KMG-2000-G

Helmholtzstr. 21, 38 – 40 | 41747 Viersen | Deutschland | +49 2162 3703-0 | [email protected] | www.gte.de

Force  measuring  device  for  doors 

and gates.

Содержание KMG-2000-G

Страница 1: ...EN Operating manual KMG 2000 G Helmholtzstr 21 38 40 41747 Viersen Deutschland 49 2162 3703 0 info gte de www gte de Force measuring device for doors and gates ...

Страница 2: ...ieelektronik GmbH Helmholtzstr 21 38 40 41747 Viersen Germany Support Hotline 49 2162 3703 0 E mail info gte de 2022 GTE Industrieelektronik GmbH This document and all figures contained may not be copied changed or distributed without explicit approval by the manufacturer Subject to technical changes ...

Страница 3: ...ckground combines three consecutive individual measurements into one measuring point average value in accordance with the standard specifications The generous data memory of the KMG 2000 G offers space for 500 complete individual measurements or 166 complete standard measurements The following four measured values are determined for each measurement in order to assess the closing force in accordan...

Страница 4: ...5 1 Overview KMG 2000 G 5 5 2 Function 6 6 Menu Options 6 6 1 General Notes 6 6 2 Options Menu 6 6 2 1 Option 1 Activation Mode 6 6 2 2 Option 2 Delete Mode 7 6 2 3 Option 3 Check on Measured Values Held in Memory 7 6 2 4 Option 4 Lightning Adjustment 8 6 2 5 Option 5 Buzzer 8 6 2 6 Option 6 Switch off Time 8 6 3 Language Selection 9 7 Measurement Preparation 9 7 1 Turn on the KMG 2000 G 9 7 2 Per...

Страница 5: ...01 EN34 TABLE OF CONTENTS 10 Warnings and Error Massages 11 10 1 Battery Monitoring 11 10 2 Memory Space 12 10 3 Memory Space Empty 13 10 4 Device Still Loaded 13 11 Calibration 13 12 Disposal 13 13 Technical Data 14 ...

Страница 6: ...tructions Operational objectives are shown in bolt print Marking Explanation Z This is followed by an instruction 1 Step by step instructions Instructions for action are numbered in the order of their appearance Results of action steps Lists without a defined sequence Warnings This manual uses the following information types DANGER This combination of symbol and signal word indicates an immediatel...

Страница 7: ...2000 G safely it is essential to read understand and follow these instructions and the safety instructions contained therein 2 1 Intended Use The force measuring device KMG 2000 G is used for routine checking of closing forces on gates and doors after new installation or for the prescribed annual inspection of existing gates with entry in the inspection book belonging to each gate Via the built in...

Страница 8: ...ds EN 16361 Power operated doors Product standard performance characte ristics Door systems other than swing doors intended for power operation ASR 1 7 Technical rule for workplaces doors and gates TS011 and TS012 DHF Code of practice for powered gates barriers 2 3 Qualification of Personnel All work with the KMG 2000 G may only be performed by qualified personnel Qualified persons are those who c...

Страница 9: ... Property damage caused by using the wrong components The use of parts other than the original spare parts and the original accessories of the manufacturer can lead to property damage Only original spare part and original accessories of the manufacturer may be used The following accessories are available for the KMG 2000 G Product Distance Set Software KMG VD 2005 1 2 3 ...

Страница 10: ... to incorrect storage conditions Mechanical loads caused by improper transport will result in material damage to the KMG 2000 G No mechanical stress may occur during transport 5 Setup and Function 5 1 Overview KMG 2000 G 1 2 3 4 5 6 1 Measuring surface 2 Enclosure 3 Display 4 Softkeys 5 Handle 6 Battery compartment ...

Страница 11: ...alling up menu functions and for operating the device The function of the keys is given by the symbols F1 F2 and F3 on the display If keys are not represented by these F symbols on the display then these keys have no function or all keys have the same function For approx 5 seconds after switching on the KMG a menu is displayed allowing Options and Language to be selected F1 Options Call up menu fo...

Страница 12: ...nce more in a further menu whether the measured values selected should be deleted F1 Yes F3 No By actuating F1 the data selected will be deleted 6 2 3 Option 3 Check on Measured Values Held in Memory In order to prevent accidental deletion button F2 must be pressed for longer than 3 seconds The following delete functions can be selected on the delete menu F1 entire memory is deleted F2 last indivi...

Страница 13: ...ions Next function Illumination 4 6 F1 F2 F3 On this menu the internal buzzer can be switched on or off using button F1 The buzzer gives an audible signal once measuring has been completed Exit Options Next function Beeper 5 6 F1 F2 F3 The device does not have an on off switch After the device has been switched on by pressing any button as desired it switches off automatically after a period of ti...

Страница 14: ...Press any key Ö KMG 2000 G is switched on After switching on the start display appears for 5 seconds During this time the language selection or the options menu can be selected After 5 seconds the device is ready to carry out force measurements The current status of the measured value memory is displayed top left e g 2 Normal measurement 3 Individual measurement 7 2 Performing Measurement A measur...

Страница 15: ...ime graph over the measurement period 5secs is initially displayed and the dynamic force Fd peak force is displayed as a value Button F1 To switch between normal display 5 sec measuring range and zoom display of the dynamic range 1sec measuring range Button F2 To switch to display of 4 measured values Max dynamic force Fd in N Static force Fs in N End force after 5 seconds Fe in N Duration of dyna...

Страница 16: ...nnection or malfunctions The KMG 2000 G can store a total of 500 graphs equivalent to 166 standard measurements with 3 individual measurements The data is preserved even after the device has been swit ched off with the result that the force graphs can also be read off the KMG 2000 G during a subsequent period The individual functions can be called up via the program menu of the software You can fi...

Страница 17: ... the charging time is approx 3 4 hours Operating display a without KMG connection LED green b charging process LED red c charging process completed holding charge LED green for 19 secs and red for 1 sec The average power consumption in case of an unilluminated display is approximately 20 mA and in case of an illuminated display approximately 40 mA This gives an operating life of approximately 80 h...

Страница 18: ...e sent to for calibration at least once a year 12 Disposal Send the KMG 2000 G back to the manufacturer at the end of its useful life This ensures environmentally friendly disposal of all components If the KMG 2000 G is loaded with a force of more than 50 N when a measurement is started manual ly further measurement is possible F3 key but the measurement accuracy is no longer guaranteed The follow...

Страница 19: ...rd measurements with 3 indi vidual measurements each Temperature range 10 60 C Relative humidity 20 90 rF non condensing Test surface dimensions 80 mm Ø height 50 mm Dimensions 310 mm x 80 mm x 50 mm l x b x h Weight 1400 g Measuring range 25 N 2000 N Measuring accuracy Typ 10 N Measurement error 25 N 200 N 10 N 200 N 2000 N 5 v measured value Spring constant 500 N mm Rise fall time 5 ms ...

Страница 20: ......

Отзывы: