FST 75/150
260-2210-002 EN064
Page 12 / 37
Configuration
-.- = Position start. Once you have selected such a menu item, press the motion buttons.
(W) = Factory setting
Basic Settings
0.1
Operating mode
save
W
1
Dead-man control in open and close direction
2
Self-stoping run in the direction of “open” and dead-man control
in the direction of “close”
3
Self-stopping run in the direction of “open” and “close”
Auto switching to dead-man control with internal key or key pad in the event of
an error occurring in the safety device
Press the rotary
switch
4
Self-stopping run in the direction of “open” and “close”
Auto switching to dead-man control with internal key or key pad in the event of
an error occurring in the safety device
0.2
The safety edge “close“ – How it works
save
1
Without reverse
2
With reverse 1 second after “open”
Press rotary switch
W
3
With reverse up to “open” position
0.3
The safety edge “open“ – How it works
save
1
Without reverse
W
2
With reverse 1 second after “close”
Press rotary switch
3
With reverse up to “close” position
0.5
Rated frequency of the motor
save
w=50
10..200 Rated frequency of the motor in Hz.
Press rotary switch
0.6
Maximum voltage boost
save
w=30
0..40
Maximum voltage boost on motor startup
Press rotary switch
0.8
Safety Photocell in close direction - function
save
1
Stop in close direction without reverse
2
With reverse 1 second in open direction
Press rotary switch
W
3
With reverse up to open position
4
Stop with run in close direction afterwards