1. SAFE TY RULES

  

This meter is designed for indoor use at temperatures between 0°C to 40°C and 
altitudes up to 2,000m.

  To ensure that the meter is used safely, follow all safety and operating instructions in 

this operation manual. If the meter is not used as described in this operation manual, 
the safety features of this meter might be impaired.

   Do not use the meter if the meter or test leads look damaged ,or if you suspect that 

the meter is not operating properly.

   When using the instrument, keep your fi ngers behind the fi nger guards on the plastic 

casing and probes.

   Disconnect the live test lead before disconnecting the common test lead.

   Make sure power is off before cutting, desoldering, or breaking the circuit wires. Small 

amounts of current can be dangerous.

  Do not apply more than 600 VDC or 600V AC rms between a terminal and ground.

   To avoid electrical shock, use CAUTION when working above 60V DC or 25V AC 

rms. Such voltages pose a shock hazard.

   Never make measurements with the battery cover off.

  To avoid electrical shock or damage to the meter, do not exceed the input limits.

2. INTERNATIONAL SYMBOLS

 

  

Important information  

 Dangerous Voltages 

 

see manual  

  Continuity

 

  AC  

 Ground

 

  DC 

   Double Insulation

3. TECHNICAL SPECIFICATIONS

3.1 General Specifi cations

Display:  

3-3/4 digits LCD, max. of 3999 display  

 with 

 

decimal point and engineering units 

Polarity: 

Automatic, (-) negative polarity indication

Zero adjustment:  

Automatic

Sample rate: 

0.5 Sec.

Over range indication:   Reading 

“ ”

 is displayed

Power:  

9-volt battery type NEDA 1604, IEC6F22

Battery life: 

Approx. 50 hours. (w/ alkaline batteries)

Dimension:  

141 x 69 x 36 mm.

Weight:  

Approx. 160g  (including battery).

Accesories: 

User’s Manual, Alligator Clip, Probes    

 

Cups and 9V alkaline battery 

3.2 Electrical Specifi cations

The mark    next to the probe tip, is a warning that the input 
voltage should not exceed the indicated values. This is to pre-
vent personal injuries and damage to the internal circuitry.

The function switches should be set to the function which you 
want to test before operation.

Accuracies are ±(% of r number of least signi

fi

 cant 

digits) at 23°C ±5°C, less than 75% RH.

4. OPERATION

4.1 Instrument Description

1) Case

2) 3-3/4 Digit LCD display

3) ON/OFF and Range switch

4) Function switch

5) Fixed test lead with probe

6) Fixed probe tip and fuse cap

7) Battery cover

8) Display hold push button (back of the unit)
9) Probes cups

10) Alligator clip

Function

Range

Accuracy

Input 

Impedance

Remarks

Overload 

Protection

DC Voltage

4000mV, 60V  

600V

0.8%+1

10 M

-

600 Vp-p

AC Voltage

4000mV, 60V

600V

1.2%+3

10 M

40~400Hz

600 Vp-p

DC Current

40 - 400 mA

1.2%+3

-

-

400 mA/

250V Fuse

AC Current

40 - 400 mA

1.2%+5

-

40~400Hz

400 mA/

250V Fuse

4.2 Display Description

4.3 Measurement Procedures

 

 

CAUTION

:  Maximum Input Voltage is 600Vrms,do not exceed 

this rating to avoid personal injuries or damage to 
the instrument. The range FUNCTION/RANGE 

switch should be set to the range you want to test 
before the operation.

  

CAUTION

:  Always ensure that the correct terminals are used for 

the type of measurement to be made. Avoid making 
connections to “live” circuits whenever possible.
When making current measurements ensure that 
the circuit is not “live” before opening it in order to 
connect the test leads.

Function

Range

Accuracy

Input         

Impedance

Remarks

Overload 

Protection

Resistance

400

, 4k

40k

,400k

4M

1.0%+2

-

1.2 mA 

max. test 

current

250 Vp-p

40 M

1.5%+2

-

0.47 mA 

max. Test 

current

250 Vp-p

Diode Test

Test Current:1.0± 0.6mA

Test Voltage: 3.2 V Max.

250 Vrms

Continuity

Beeps when < 100

Ω

3VDC Max. Test Voltage

250 Vrms

Logic level

Logic High > 2.0V

Logic Low < 0.8V

250 Vrms

8.8.8.8

DH

HI

LO

MK

Ω

mVA

Replace battery

Data hold

TTL logic status

Continuity
beeper enable

Measurement units

Digital reading

AC

Neg. polarity

DC

1

2

3

4

8

6

9

10

5

7

8.8.8.8

DH

HI

LO

MK

:

mVA

CT

8022

 