GK600 User Manual
Chapter 6 Specification of Parameters
-
191 -
Under SVC pattern, adjustment of this parameter value can improve the speed accuracy when
driving power generating load. If the load is becoming heavier and the motor speed is relatively
higher, set a bigger value, while the motor speed is relatively lower, set a smaller value.
Group d3 Parameters of Motor 2
When motor 2 is selected as current loaded motor, set motor parameters in Group d3. The
specification of parameters of motor 2 in Group d3 is exactly the same with that of parameters
of motor 1 in Group d0.
d3-00 Type of motor 2
Range: 0~2
Factory default: 0
d3-01 Power rating of motor 2
Range: 0.4kW~6553.5kW
Factory default:
model dependent
d3-02 Rated voltage of motor 2
Range: 0V~480V
Factory default:
380V
d3-03 Rated current of motor 2 Range: 0.0A~6553.5A
Factory default:
model dependent
d3-04 Rated frequency of motor 2
Range: 0.00Hz~upper limit
frequency
Factory default:
50.00Hz
d3-05 Pole number of motor 2
Range: 1~80
Factory default: 4
d3-06 Rated speed of motor 2
Range: 0~65535 r/min
Factory default:
model dependent
d3-07
Stator resistance R1 of
motor 2
Range: 0.001Ω~65.535Ω
Factory default:
model dependent
d3-08
Leakage inductance L1 of
motor 2
Range: 0.1mH~6553.5mH
Factory default:
model dependent
d3-09
Rotor resistance R2 of
motor 2
Range: 0.001Ω~65.535Ω
Factory default:
model dependent
d3-10
Mutual inductance L2 of
motor 2
Range: 0.1mH~6553.5mH
Factory default:
model dependent
d3-11 No-load current of motor 2 Range: 0.0A~6553.5A
Factory default:
model dependent
d3-12
Flux weakening coeff 1 of
motor 2
Range: 0.0000~1.0000
Factory default:
model dependent
d3-13
Flux weakening coeff 2 of
motor 2
Range: 0.0000~1.0000
Factory default:
model dependent
d3-14
Flux weakening coeff 3 of
motor 2
Range: 0.0000~1.0000
Factory default:
model dependent
d3-22 Autotuning of motor 2
Range: 0~2
Factory default: 0