Page 21
Terminal Shut Down
When powering off the GT8 it is advisable to perform a shut down operation. The shut down utility will stop
all processes and perform a graceful shut down allowing power to be safely removed.
Note:
If power remains on the unit it will re-start after a delay.
Note:
The battery backup will continue to run the GT8 following a power failure until the battery capacity
reaches its lower threshold, when the graceful shut down will be triggered. The unit will be powered off at the
end of the process.
Note:
The shut down utility allows the GT8 to be powered off without exhausting the battery. To power down
the unit run the utility until the unit has completed its shut down then remove the power. If power is left
connected the unit will re-start after a delay.
To trigger the shut down process or perform a re-boot.
1.
Enter terminal set up (press admin icon)
2.
Enter PIN (the default is 1905)
3.
Select shut down
4.
Select shut down or reboot as required
Note:
To completely power off the terminal
disconnect the power supply once the terminal has
shut down (PSU and/or POE+).
Note:
Terminal will not boot/reboot if running on
battery only.