- 19 -
STI 1932 CT
56
Herein the current system temperature as well as date and time of the last
login is displayed.
—> If a system temperature of 85°C will be reached, the system will be
shut down.
57
Via button
Logout
you can leave the graphical user interface.
58
Via the
Help
menu you can call up the assembly instructions (PDF), hints
about the configuration of a multicast network (PDF) as well as a ZIP file
containing a list and all licences of the used OpenSource software.
59
Overview of the transponder set, with output frequency, TS-/ON ID, Multi-
cast address and data rate. Via the background colour of column
Line
you
are informed about the quality of the input signals ( good/ no signal),
a possible exceeding the output data rate ( ), or whether the output is
switched off ( ).
—> If in menu Configuration/Input (page 20) transponder names are
NOT assigned, the name of the first station of each transponder is
displayed.
60
Hardware monitoring; shows the state of the power supplies and the fans
61
Via button
Download
a configuration protocol can be stored as text file
resp. opened using a text editor.
—> From this protocol file e.g. a list of the programmed stations can be
prepared using e.g. a text editor.
P
erfor m
Changes
Before leaving a menu
, changes must be transmitted to the head-end station.
• Therefore click on button
.
After that
is displayed for a short time in the upper right corner.
n
umber
for m at
For entering/indication of the different IDs the number format can be set to
hexadecimal or decimal in menu
System > Firmware
.