3.6  r

etrofit ting

 

a

 Ca 

module

 

The cassette is equipped with a common interface. It allows you to connect a 
CA module for various encryption systems and service providers. Scrambled 
services can only be descrambled with a CA module suitable for the scram-
bling system and the corresponding smart card. The smart card contains all 
the information for authorisation, descrambling and subscription.

 

–  Check with the distributor or manufacturer of the CA module to be used 

to ensure that it is suitable for descrambling several services. 

 

–  The hardware and software of this cassette have been thoroughly prepared 

and tested.

 

 

Any changes made by service providers in the data structures might impair 
or even prevent this function.

 

–  When working with the CA module, please read the corresponding operat-

ing manual from the respective provider.

 

•  Insert the smart card 

1

 into the CA module 

2

 so that the chip 

3

 on the 

smart card faces the thicker side (top) of the CA module.

 

•  Insert the CA module into the guide rails of the CA slot 

4

 with the top side 

of the CA module facing the top side of the cassette.

 

•  Push the CA module without canting into the guide rails of the CA slot 

4

 

and contact it to the common interface.

3

4

1

2

Содержание PTIS 1000

Страница 1: ...Assembly Instruction PTIS 1000 ...

Страница 2: ...1 Menu items 14 4 2 Control panel 14 5 Programming 15 5 1 Programming procedure 15 5 2 Programming the cassette 17 Selecting the cassette displaying the software version 18 Ethernet parameters 18 IP address of the cassette 19 Address range 19 Address of the gateway 20 UDP port 20 Input transport stream 21 Setting the input channel 21 Setting the hierarchical modulation 23 Allocating the IP address...

Страница 3: ...locating IP addresses to services automatically 27 Allocating services manually 28 Selecting the sound options of the service 29 Switching DVB service information on or off 29 Displaying the output data rate 30 Factory reset 31 Saving settings 31 Operation with a CA module 32 Setting the PID monitoring 32 Configuring the CA module 32 Descrambling services 34 6 Final procedures 35 ...

Страница 4: ...s No liability is accepted for any damage caused by faulty connections or inappropriate handling Observe the relevant standards regulations and guidelines on the installa tion and operation of antenna systems The standards IEC EN DINEN50083 and IEC EN DINEN60728 must be observed For further information please read the assembly instructions for the head end station used Test the software versions o...

Страница 5: ...es 2011 65 EU 2014 30 EU 2014 35 EU The product fulfils the guidelines and standards for CE labelling page 36 Unless otherwise noted all values are specified as typical RF input Channels C05 C12 C21 C69 Frequency range 177 5 226 5 474 858 MHz Input level 60 dBμV 80 dBμV Loop through output gain 0 dB 3 dB Return loss 8 dB Impedance 75 Ω Symbol rate acc to EN 300744 LAN interface Standard 100 BASE T...

Страница 6: ...input 17 dB 5 270 MHz Connections RF inputs 2 IEC sockets RF loop through outputs 2 IEC sockets RF output 1 IEC socket no function LAN 1 RJ 45 socket ASI input 1 BNC socket ASI output 1 BNC socket Connection strip 10 pin for supply voltages and control circuits RS 232 socket serial interface for software update Common Interface 1 several services can be descrambled ...

Страница 7: ...e Tuner A Tuner B channel strips and from the transport streams supplied via the ASI socket ASI Asynchronous Serial Interface according to DIN EN 50083 9 can take up to 16 services and are each assigned an IP address The signal supplied into the ASI input is provided again via the ASI output Principle signal path TPS Tuner A Tuner B CA Modul CA module ASI input ASI output IP address Port Service 1...

Страница 8: ...r a data transfer is in progress When the head end station is switched on the two line LC display shows the software version of the control unit To operate this cassette the software version of the control unit must be V 45 or higher You can find the current operating software for the control unit and the cassette the software BE Flash and the current assembly instructions on the website www mygss...

Страница 9: ...n that vibrates in a similar way Before installing or changing a cassette unplug the power cable from the mains power socket Remove the fastening screws 1 of an unoccupied slot from the bracket of the head end station Insert the cassette in this slot and push it into the housing Align the cassette and apply slight pressure to connect it to the connections of the board and the RF bus bar Fasten the...

Страница 10: ...nd out for the 19 cabinet are made using cable terminals CLASS KLASSE The attenuation of shielding of the connection lines for ASI and antenna must meet the requirements for Class A Insert the required number of cable terminals in the openings provided in the head end station or in the 19 cabinet Tighten the nuts of the cable terminals until the teeth on the lock washers put un der have penetrated...

Страница 11: ...ut of RF input 4 7 Status LED of the LAN interface yellow LED data transfer 8 LAN socket 9 Status LED of the LAN interface green LED network connection 0 ASI input ASI output Type label Slot for a CA module D SUB socket RS 232 MAC address 3 4 Connecting the cassette Connect the RF connections to the inputs 4 channel strip A and 1 channel strip B Connect the LAN socket 8 Connect the ASI input 0 and...

Страница 12: ...erating software of the cassette at the website www mygss eu Use a one to one cable to connect the cassette s RS 232 interface and the PC according to the wiring scheme below 9 pin D SUB socket 9 pin D SUB plug 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 For PCs with USB connector without serial interface we recom mend the DeLOCK USB 2 0 to Serial adapter Product No 61460 Start the BE Flash software and u...

Страница 13: ...for descrambling several services The hardware and software of this cassette have been thoroughly prepared and tested Any changes made by service providers in the data structures might impair or even prevent this function When working with the CA module please read the corresponding operat ing manual from the respective provider Insert the smart card 1 into the CA module 2 so that the chip 3 on th...

Страница 14: ...lined Use the button to select the following main menu items Setting Ethernet parameters Selecting the input Allocating the IP addresses Displaying the data rate Factory reset 4 2 Control panel The key pad on the head end station is used to scroll through the menus scrolls forward through the menus select parameters in the menus set values initiate actions selects sub menus scrolls backward throug...

Страница 15: ... 255 0 IP MASK Bx 4 192 168 0 128 IP ADDR Bx 4 60000 UDP PORT B 0 65535 Ein On Tuner A Tuner B ASI Bx 4A C60 786 0 INPUT OK Bx 4 Tuner A OK INPUT Frequenz Feinabstimmung Frequency Fine tuning C5 C12 C21 C69 64 64 Tuner A Tuner B Bx 4A Priority high INPUT high low Kanalzug A mit CA Modul Channel strip A with CA module Bx 4A Menu CA Edit Bx 4A TV X 01 06 X entschlüsseln descrambling 0 nicht entschlü...

Страница 16: ...T txt SDT sdt ON off all 01 IP 1 all AUDIO copy 1 7 copy auto auto M B A Bx 4A Defaults FACTORY Bx 4A STORE FACTORY M Werkeinstellwerte aufrufen invoke factory defaults Bx 4A Menu CA Edit Bx 4A 01 03 Information MENU Bx 4A TV X 01 06 X entschlüsseln descrambling 0 nicht entschlüsseln no descrambling X 0 nächster Service next service PID Check on on off Die angezeigte Information ist abhängig vom v...

Страница 17: ...ntries that have not been saved are reset to the previous settings Entries in the menus can be saved by pressing the key You are taken back to the Selecting the cassette menu item Pressing the button returns to the previous menus Switch on the head end station BE Remote please wait V 45 t 10 s Ein On The display shows the software version e g V 45 The processor reads the cassettes data approx 10 s...

Страница 18: ...te Press the button The Ethernet parameters ETHERNET menu is activated Ethernet parameters In this menu you specify whether the Ethernet parameters for the cassette are entered automatically by a connected server DHCP or whether you want to enter them manually stat To assign the cassette uniquely each IPTV cas sette must be allocated its own IP address Bx 4 stat ETHERNET Options Press the buttons ...

Страница 19: ... that the data is provided by a DHCP server Bx 4 192 168 0 128 IP ADDR Use the buttons to place the cursor under the digit of the IP address displayed to be set and use to set the desired IP address Press the button The Address range IP MASK menu is activated Address range In this menu you define the address range for the cassettes connected to the LAN network Bx 4 255 255 255 0 IP MASK Use the bu...

Страница 20: ...he button The UDP port UDP PORT menu is activated UDP port The UDP port setting is required if the cassette needs to be reached externally to make the setting such as from another input frequency This setting is in tended for future functions and can be skipped for this cassette Bx 4 60000 UDP PORT Use the buttons to place the cursor under the digit of the port number displayed to be set and use t...

Страница 21: ...e menu Allocating IP addresses IP OUT 1 is activated page 24 Input transport stream selected Tuner A or Tuner B Press the button The menu Setting the input channel INPUT is activated Setting the input channel Once the RF receiver has synchronised to the input signal OK is displayed If appears in the second line of the display there is no input signal present Check the configuration of the antenna ...

Страница 22: ... addition to the indicator in the display there is also a status LED which indi cates whether a transport stream is received or not LED indicator Indication Green Signal available Red No signal Press the button The menu Setting the hierarchical modulation INPUT Priority is activated Status LED Channel strip B Status LED Channel strip A ...

Страница 23: ...ion conditions the receivers can receive both data streams in poorer reception conditions only the HP portion Bx 4A Priority high INPUT By pressing set to high or low not relevant in the case of standard modulation Press the button The Selecting the input transport stream INPUT menu is acti vated when the input signal source Tuner A without a CA module installed and Tuner B are programmed page 21 ...

Страница 24: ...IP OUT 1 IP OUT 16 In the second line of the display the service is indicated allocated to the IP output e g Das Erste If no service is found or allocated the display shows instead of the name of the service Press the button The Switching the IP address off or on Selecting the transmission protocol Setting the port number MODE PORT menu is acti vated Switching the IP address off or on Selecting th...

Страница 25: ...ol is for continuously transmitting mul timedia data streams in an IP network Unlike UDP the header is transmitted which makes the data transmission more robust Setting the port number Press the button to position the cursor under the port number e g 1234 Use the buttons to position the cursor under the digit of the port number displayed to be set Using the buttons set the port number wished 0 655...

Страница 26: ...ine the quantity of MPEG data packets in one IP data packet 1 7 Setting the forward error correction Press the button to position the cursor under off In position off the forward error correction FEC is switched off Using the buttons set the value of the FEC wished off 10 9 20 19 IP 1 7 10 09 PKTS FEC AnnexB Setting the transmission channel Press the button to position the cursor under Annex Use t...

Страница 27: ...exclamation mark ap pears in the first line of the display beside the number of the IP output IP 1 227 40 50 60 OUT IP Allocating IP addresses to services manually Press the buttons to position the cursor under the digit of the IP ad dress to be set Using the buttons set the IP address wished Allocating IP addresses to services automatically Pressing the button the first 16 of the present services...

Страница 28: ... 001 016 The 1st of 16 services is being allocated to the IP ad dress Das Erste Name of the service Further possible terms displayed RA Type of the service Radio For radio stations the background of the screen of the connected TV or test receiver is darkened The star means that the TV or radio station selected is scrambled To enable the stations the CA module and the appropriate smart card of the ...

Страница 29: ...ges Dual sound 2ch or AC3 are transmitted in a service you can select the desired audio stream from the transport stream in this menu IP 1 all AUDIO Press to select the desired sound option e g all deu German 2ch etc Press the button The Switching DVB service information on or off OPTIONS menu is activated Switching DVB service information on or off In this menu the transmission of the DVB servic ...

Страница 30: ...ed to all IP addresses The display shows copy for a short time Press the button The Allocating the IP addresses IP OUT menu is activated page 24 Repeat the settings until all services wished are allocated to an IP address Press the button The Displaying the output data rate DATARATE menu is activated Displaying the output data rate In this menu the current output data rate is displayed Bx 4A 72956...

Страница 31: ...ut invoking the factory defaults page 18 Press the button The factory defaults are saved The display shows STORE Back to Selecting the cassette page 18 By pressing the button you will be returned to the menu item Setting the Ethernet parameters without saving the factory defaults page 18 Saving settings Press the button The settings are saved You will be returned to the Selecting the cassette menu...

Страница 32: ...tched on If particular PIDs are not descrambled the CI module is reset Additionally dropouts may occur if several services are descrambled To prevent this the PID monitoring can be switched off Bx 4A PID Check CA on Use the buttons to switch off or on the PID monitoring Press the button The Configuring the CA module CA menu is activated Configuring the CA module The menu varies according to which ...

Страница 33: ...le is activated For the explanation of further details please use the operating instructions of the CA module used Use the buttons to activate the menu desired Press the button to activate the menu Use the buttons to select the function desired To set the CA module use the and buttons All settings are saved by pressing the button You will be returned to the Configuring the CA module CA menu item B...

Страница 34: ...currently selected service will be descrambled 04 09 The 4th of 9 services read is being displayed Name of the service Further possible terms displayed RA Radio type of service 0 The currently selected service remains unchanged Use the buttons to call up the services in sequential order which are to be decoded then use to decrypt X or not to decrypt them 0 Save changes and activate the filter Pres...

Страница 35: ...ttes it is necessary to tighten all cable connections cable terminals and cover screws in order to maintain compliance with current EMC regulations securely Securely tighten the cable bolted connections using an appropriate open ended spanner Mount the front cover see assembly instructions of the head end station ...

Страница 36: ... 43 D 90471 Nuremberg CLASS CLASS KLASSE KLASSE Phone 49 0 911 703 8877 Fax 49 0 911 703 9210 www gss de en info gss de Service Phone 49 0 911 703 2221 Fax 49 0 911 703 2326 service gss de Alterations reserved Technical data E O E by GSS Grundig Systems GmbH V39 001 2017 ...

Отзывы: