- 23 -
PSCU 6000
If "Err."(Error) is displayed in column BER, the digital TV channel
was detected, but is
not
locked at the moment.
Picture on the display (menu setting "
extended
"):
514,0 MHz A
Seite 1/1
Kanal Name
BER
dBµV
C 27
BR-3
93
514,00 6,900 Ms 1e-7
75
674,00 6,900 Ms 1e-7
75
850,00 6,900 Ms 1e-7
74
In the footer of the OSD menu the channel centre frequency (in steps
of 7 resp. 8 MHz), the type of modulation (e.g. "
A
"), the current
page (Seite) and the number of pages are displayed.
Meaning of the letters:
A = 64 QAM/6.900 MSymb/s
B = 64 QAM/6.875 MSymb/s
C = 64 QAM/6.111 MSymb/s
D = 128 QAM/6.547 MSymb/s
The search finally explores the frequency range of 87.5 MHz to
108 MHz in steps of 50 kHz for FM radio stations. The HF level is
used as criterium for FM radio stations. If a radio station is found, it
is tried to determine the station name via the RDS data. The HF level
is measured and stored as reference value for the control function.
For FM stations without RDS identification signal, blanks are entered
as station name.