Assembly Instruction
RLC 8
Страница 1: ...Assembly Instruction RLC 8 ...
Страница 2: ... unit 7 3 Installation 8 3 1 Potential equalisation PE 8 3 2 Assembling a connection cable 9 3 3 Connecting components 9 4 Installing the software on a PC or laptop 10 3 1 Key Code Activation Code for the software 10 3 2 Installing the software 10 5 Connecting to a network 14 5 1 LAN configuration 14 5 2 Check the configuration at the control unit of the head end station 16 6 Firmware update 17 7 ...
Страница 3: ...ell as the relevant safety instruc tions e g the standards EN DINEN50083 resp IEC EN DINEN60728 Take action to prevent static discharge when working on the device 2 General information 2 1 Packing contents 1 RLC 8 1 network cable 2 m 8 RS 232 plug 9 pin Sub D 8 RS 232 sockets 9 pin Sub D 1 ribbon cable 9 pin 1 Power supply unit 1 Brief assembly instruction 2 2 Meaning of the symbols used Important...
Страница 4: ...80 DNS port 53 UDP TCP Monitoring cassette PSCU 6000 HSCU 6000 The following items are signalled Level of the output signal measured via PSCU 6000 HSCU 6000 BIT error rate at QAM output signals Present line synchronizing signal at analogous PAL output signals Present RDS station name at FM output signals Quality of the input signal good poor and no signal at QPSK PAL double transmodulators as well...
Страница 5: ...PC or a network via the LAN interface and enables communication between the PC and the connected head end stations LAN 8 x RS232 Therefore the Windows software PSW 1000 ist needed A connection to the Internet and thereby remote control is possible via a router Hardware concept ...
Страница 6: ...nits BE Remote to a PC network The monitor ing cassette PSCU 6000 HSCU 6000 is also supported Error messages from the PSCU 6000 HSCU 6000 monitoring cassette can be forwarded by e mail Required index levels for remote control and remote updates PSW 1000 index level V65 BE Remote index level V45 2 5 PC laptop system requirements System requirements for the PSW 1000 software PC or laptop with a Pent...
Страница 7: ... management unit 1 3 4 2 5 6 1 1 Mounting support 2 Potential equalisation screw 3 RS 232 interfaces Connectors for the head end stations or a PSCU 6000 HSCU 6000 LEDs Rx LEDs Tx 4 DC socket 5 V 5 LAN socket 6 USB sockets not used ...
Страница 8: ...al suitable for the wall properties Attach four mounting screws at the installation site The drilling distances are shown in the drawing below 1 1 218 mm 146 mm 2 Hang the unit with the mounting supports 1 on the 4 screws Tighten the screws 3 1 Potential equalisation PE Make a potential equalisation PE according to IEC EN DINEN50083 resp IEC EN DINEN 60728 Connect the PE connection terminal 2 to a...
Страница 9: ...d length Insert the ends of the cable into the openings on the RS 232 plug and RS 232 socket making sure they are pushed in all the way Firmly close the sliders on the blade contacts 3 3 Connecting components Connect up to 8 head end stations 7 head end stations 1 monitoring cas settes PSCU 6000 HSCU 6000 to the RS 232 interfaces 3 by using self made 1 1 RS 232 cables Connect the attached power su...
Страница 10: ...r the activation of the PSW 1000 software This can be obtained from your regional authorised distributor 3 2 Installing the software The PSW 1000 software can be downloaded from www mygss eu If you do not have Internet access we will send you a DVD on request Unzip the PSW1000_Vxx zip file and start the setup_PSW1000_Vxx exe programme by a double click Select the desired language and click the OK ...
Страница 11: ...e agreement select I accept the agreement and click the Next button Keep the software version of the PSW 1000 always up to date in order to be able to remote control also the newest products After installing the PSW 1000 soft ware update the software for the cassettes if necessary Click the Next button ...
Страница 12: ...fy the directory in which the PSW 1000 should be installed e g C Programme GSS PSW1000 Click the Next button Enter a name for the shortcut to the programme which will be created in the start menu Click the Next button ...
Страница 13: ... RLC 8 Click on Install in order to proceed with the installation of the programme or on Back to make corrections or changes The installation progress is shown Click on Finish to complete the installation ...
Страница 14: ...several RLC 8 are used in the network different IP addresses must be assigned for the RLCs Set a static IP address to your PC which is in the address range of the RLC 8 e g 192 168 0 2 Connect your PC directly to the RLC 8 via a LAN cable Start any internet browser Enter the IP address of the RLC 8 http 192 168 0 120 at the address line of the browser and press the Enter button Enter the user name...
Страница 15: ... 65000 On request change the password Note the settings Click the Apply button in order to save the changes The changed settings are transmitted to the RLC 8 The RLC 8 will be rebooted Now the RLC 8 is configured for your LAN network Disconnect the LAN connection to your PC Connect the RLC 8 to your network ...
Страница 16: ...em informatio n control unit SYSTEM INFO BE_Remote menu appears The System information software also can be called up from the stand by mode of the display SYSTEM BE Remote INFO V 45 Press the button so many times until the network configuration is shown in the display of the RLC 8 REMOTE 1 9 2 1 6 8 0 0 0 1 2 0 IP ADDR Press the button REMOTE 2 5 5 2 5 5 2 5 5 0 0 0 IP MASK Press the button REMOT...
Страница 17: ...the Enter button Enter the user name admin and the password geheim is the standard value and click the Login button In section Firmware the current firmware version is indicated Check whether a newer version is available on www mygss eu Download and unpack it to your PC Click on button select the stored file and click on but ton Open ...
Страница 18: ...ction of the router If several RLC 8 are used for each port used Port Forwarding must be configured To get remote access via internet you need a PC with internet access Start the PSW 1000 software The installation of the PSW 1000 software is described in chapter 4 page 9 Click the button The Connection settings window is activated Select tab Ethernet and enter Select tab Ethernet and enter at a co...
Страница 19: ...k on button OK The connecting button changes from to If you have entered a wrong password the following message appears Enter the password case sensitive The connecting button changes from to The password setting is to be done in menu Plant settings Security PSW 1000 ...
Страница 20: ...ße 43 D 90471 Nuremberg CLASS CLASS KLASSE KLASSE Phone 49 0 911 703 8877 Fax 49 0 911 703 9210 www gss de en info gss de Service Phone 49 0 911 703 2221 Fax 49 0 911 703 2326 service gss de Alterations reserved Technical data E O E by GSS Grundig Systems GmbH 001 2017 ...