Models:

INV600-12, INV600-24

INV1000-12, INV1500-24,

INV1500-12, INV2500-24, 

INV2500-12

Modified Sine Wave

 DC to 240VAC Power Inverters

12VD

Operating Instructions

Please read these instructions before use

Unit 2, 110 Staton Road, Seven Hills ,NSW,  2147, Australia

Trouble Shooting:

Symptom

Possible Cause

Solution

Low AC output voltage: 190-

210VAC

Using average reading 

Voltmeter

Use true RMS meter and cable

No AC output voltage. Over 

Temp LED On. 

Insufficient ventilation around 

inverter

Ensure true power rating of 

appliance (including power 

factor) is less than inverter 

output rating

Improve ventilation

Check ratings and reduce with 

different appliance

Inverter shuts down when trying 

to start a load

Possible surge from motor 

starting causing shut down

Check that battery voltage is 

within specification. If voltage 

drops excessively when 

starting, batteries size may 

have to be increased. Or load is 

too large for inverter.

Load LED flashes

Overload

Reduce load. Remove load.

No AC output voltage. Bar 

Graph in lower RED zone.

Low input voltage

Check battery status.  

Re-charge if required.

No AC output voltage. Bar 

Graph in upper RED zone.

Excessive input voltage

Check input voltage. 

Reduce if too high.

TV channel interference on 

some channels

Connection of chassis ground 

lug at rear of inverter needs 

attention.

High power loads being used 

during TV viewing.

Ensure TV antenna providing a 

good signal.

DC power cables too long 

causing excessive radiated 

interference.

Check chassis ground lug is a 

solid connection.

Do not use high power loads.

Check antenna wiring and 

connection. Move TV away 

from power inverter.

Shorten cables if necessary 

and twist them together with 

approx. 2 to 3 twists per foot.

Warranty Conditions:

 The product is warranted to be free from defects in materials and workmanship under normal use and 

service for a period of 24 months from the date of sale. This warranty covers defective parts and workmanship provided that 

the product is shipped prepaid to the seller within 24 months of purchase of goods. This warranty is limited to the repair or 

replacement (at the manufacturers’ discretion) of parts and shipping prepaid to the original despatch destination. We regret that 

no liability can be accepted for consequential or special damages of any kind howsoever arising in connection with products 

supplied by the seller. This warranty is in lieu of all other warranties expressed or implied. No representative is authorised to 

assume for the seller any other liability in connection with the seller’s products.

INV12-24-ALL-R1

Содержание INV600-12

Страница 1: ...ot drop a metal tool on the battery as the resulting spark or short circuit of the battery may cause an explosion Remove personal metal items such as rings bracelets necklaces and watches when working with a lead acid battery A lead acid battery produces a short circuit current high enough to weld a ring or similar metal causing a severe burn Operating Limits The inverter will operate most AC appl...

Страница 2: ...V1000 1500 2500 only This bar graph displays the AC power drawn from the power inverter It indicates the load in Watts Under normal operating conditions the bar graph should display in the green or orange bars of the display If the load is excessive the number of bars being displayed will increase Should all the bars illuminate the unit will shut down to protect itself as this is in overload condi...

Страница 3: ...ter 5 Connect the cable to the Negative NEG terminal of the battery This should be the last connection made A spark when making this final connection is normal WARNING Make sure all the DC connections are tight Loose connections will overheat and could result in a fire hazard Do not operate the power inverter without connecting it to ground if used on a building site Electrical shock hazard may re...

Страница 4: ...ut voltage Reduce if too high TV channel interference on some channels Connection of chassis ground lug at rear of inverter needs attention High power loads being used during TV viewing Ensure TV antenna providing a good signal DC power cables too long causing excessive radiated interference Check chassis ground lug is a solid connection Do not use high power loads Check antenna wiring and connect...

Отзывы: