Controls and indicators:

1. 

 

ON/OFF Switch (all models):

The ON/OFF switch turns the control circuit in the power inverter on and off. It does not 

disconnect power from the power inverter. Always leave this switch in the off position before 

operating inverter.

2.

 

Over temp LED indicator (all models): 

The over temp LED indicates that the power inverter has shut down because it has become 

overheated. The power inverter may overheat because it has been operated at power levels 

above it’s rating, or because it has been installed in a location, which does not allow it to 

dissipate heat properly. The power inverter will restart automatically once it has cooled off.

3.

 

Overload LED indicator (all models):

The overload LED indicates that the power inverter has shut itself down because its output 

circuit has been short-circuited or drastically overloaded. Switch the ON/OFF switch to OFF, 

correct the fault condition, and then switch the ON/OFF switch back to ON.

4.

 

Input voltage display (INV1000/1500/2500 only):

This bar graph displays the status of the input voltage from the supply source. Under normal 

operating conditions the bar graph should display in the green area. Should the voltage either 

increase or decrease the bar graph will display in the red areas and the unit will shut down.

5. 

AC Load display (INV1000/1500/ 2500 only):

This bar graph displays the AC power drawn from the power inverter. It indicates the load in 

Watts. Under normal operating conditions the bar graph should display in the green or orange 

bars of the display. If the load is excessive the number of bars being displayed will increase. 

Should all the bars illuminate, the unit will shut down to protect itself as this is in 

overload condition.

WARNING! Shock Hazard!

Before proceeding further, ensure that the Inverter is NOT connected to any Batteries, 

and that all wiring is disconnected from any electrical Sources. Do not connect the output 

Terminals of the Inverter to an incoming AC source.

Electrical Requirements:

Before installing your inverter, please make sure that you have appropriately sized batteries. A 

battery that is too small in capacity will not allow the inverter to perform to its full specification. 

The DC cabling must be connected to the correct polarity terminals of the battery bank. (Red 

= Positive, Black = Negative). DO NOT extend the DC cable length to the inverter unless you 

are prepared to increase the diameter of the cable. If this is necessary consult your supplier or 

installer for advice. 

WARNING! 

Reverse polarity connection will blow the internal fuse and may damage the inverter 

permanently. Reverse polarity is not covered by warranty.

Page 2 of 4

Models:

INV600-12, INV600-24

INV1000-12, INV1500-24,

INV1500-12, INV2500-24, 

INV2500-12

Modified Sine Wave

 DC to 240VAC Power Inverters

12VD

Operating Instructions

Please read these instructions before use

INV12-24-ALL-R1

Содержание INV600-12

Страница 1: ...ot drop a metal tool on the battery as the resulting spark or short circuit of the battery may cause an explosion Remove personal metal items such as rings bracelets necklaces and watches when working with a lead acid battery A lead acid battery produces a short circuit current high enough to weld a ring or similar metal causing a severe burn Operating Limits The inverter will operate most AC appl...

Страница 2: ...V1000 1500 2500 only This bar graph displays the AC power drawn from the power inverter It indicates the load in Watts Under normal operating conditions the bar graph should display in the green or orange bars of the display If the load is excessive the number of bars being displayed will increase Should all the bars illuminate the unit will shut down to protect itself as this is in overload condi...

Страница 3: ...ter 5 Connect the cable to the Negative NEG terminal of the battery This should be the last connection made A spark when making this final connection is normal WARNING Make sure all the DC connections are tight Loose connections will overheat and could result in a fire hazard Do not operate the power inverter without connecting it to ground if used on a building site Electrical shock hazard may re...

Страница 4: ...ut voltage Reduce if too high TV channel interference on some channels Connection of chassis ground lug at rear of inverter needs attention High power loads being used during TV viewing Ensure TV antenna providing a good signal DC power cables too long causing excessive radiated interference Check chassis ground lug is a solid connection Do not use high power loads Check antenna wiring and connect...

Отзывы: