GSK983Ta-H/ GSK983Ta-V Turning CNC System Connection Manual
13
11. Connection between external MPG and Operation Panel
FG
DB25 female
HB+
09
HB-
22
HA-
21
+5V
12
0V
10
HA+
08
0V
11
+5V
13
04*
×10
18
-L(0V)
ESP1
19
ESP2
06
17*
×100
05
+L(+24V)
×1
16*
02*
HZ
01*
HX
Operation Panel
CM1
FG
×
100
-L(0V)
+L(+24V)
ESP1
ESP2
×
1
×
10
HZ
HX
HA+
HA-
HB+
HB-
+5V
0V
983Ta-00-783
24V light
Axis select switch
Override switch
+5V
A phase differential pulse+
A phase differential pulse
-
B phase differential pulse
+
B phase differential pulse
-
0V
Enable
signal
External MPG
Ruipu Wuxi GSK-ZSSY1468-01G-100B-05L
。
Emergency Stop
Switch
*Note: axis select signals HX,HZ of CM1 and override signals ×1,×10,× 100 of pin No. are defined by PLC, and
pin No. can be different in different visions of PLC. So, check the operations of the corresponding PLC before
connecting.