Chapter 7: TopDry Drying Floor
Assembling the Drying Floor Center Collar
The drying floor center collar assembly is used to install the TopDry floor sheet rafters.
1. Install the channel braces (B) and channel brace plates (C) to the center collar (A) using 3/8 x 1 in.
flange bolts (D) and 3/8 in. hex nuts (E).
2. Install the center collar cross channel (F) to the channel braces (B) using 3/8 x 1 in. flange bolts (D)
and 3/8 in. hex nuts (E).
NOTE:
Do not attach the center collar cross channel (F) until the floor is done.
Figure 7-4
Assembling the center collar
A
Center collar (TD-100730)
D
3/8 x 1 in. flange bolt (S-7485)
B
Channel brace (TD-100745)
E
3/8 in. hex nut (S-456)
C
Channel brace plate (TD-100460)
F
Center collar cross channel (TD-100004)
PNEG-4936
36 Ft. TopDry Autoflow
65