![GSi TopDry Autoflow Скачать руководство пользователя страница 109](http://html1.mh-extra.com/html/gsi/topdry-autoflow/topdry-autoflow_construction-manual_2275071109.webp)
Installing the Chute Controller Housing
What You Should Know
WARNING
Chute position controller enclosure weighs approximately 275 lbs. pounds. Failure
to use proper equipment and personnel when lifting could cause bodily injury or
damage to equipment.
1. Lift the housing assembly (A) onto the lower mounting gussets (B), aligning holes in the bottom of
the housing (A) with the holes in the lower mounting gussets (B).
2. Install the housing (A) to the gussets (B) with six 5/16 x 3/4 in. flange bolts (C) and 5/16 in. flange
nuts (D).
3. Field drill four holes in the bin sidewalls (E) through the four holes in the sidewall mounting brackets
(F), making sure that the holes are drilled on the peaks of the corrugation ridges.
4. Use the 5/16 x 3/4 in. flange bolts (C) and 5/16 in. flange nuts (D) to attach the housing (A) to the bin
sidewalls (E).
Figure 9-3
Installing the chute controller housing
A
Housing assembly
D
5/16 in. flange nut (S-3611)
B
Lower mounting gussets (TD-101326)
E
Bin sidewall
C
5/16 x 3/4 in. flange bolt (S-6606)
F
Sidewall mounting bracket (TD-101331)
PNEG-4936
36 Ft. TopDry Autoflow
109
Содержание TopDry Autoflow
Страница 6: ...NOTES 6 PNEG 4936 36 Ft TopDry Autoflow...
Страница 26: ...NOTES 26 PNEG 4936 36 Ft TopDry Autoflow...
Страница 46: ...NOTES 46 PNEG 4936 36 Ft TopDry Autoflow...
Страница 106: ...NOTES 106 PNEG 4936 36 Ft TopDry Autoflow...
Страница 128: ...NOTES 128 PNEG 4936 36 Ft TopDry Autoflow...
Страница 140: ...NOTES 140 PNEG 4936 36 Ft TopDry Autoflow...