
52 Smart Climate 310 rev. 03
Limiting Mist Shutoff
The controller can disable mist units when the humidity level is too
high to avoid increasing the humidity level any further. The mist
shutoff limit can be adjusted from 40 to 99% of relative humidity (or
select
Off
to disable this function).
To disable the mist units, proceed as follows:
1. Press
Mist
.
Accessible if mist units are enabled in the USER SETUP.
2. Press the down-arrow key in order to display the
Mist
Shutoff
parameter.
3. Press
Adjust
. The shutoff limit flashes on screen. Set
it to the desired value with the adjustment buttons. Mist
shutoff at 95%
Содержание Smart Climate 310
Страница 1: ...Smart Climate 310 User s Guide 895 00676 REV 04 890 00582 REV 03...
Страница 12: ...12 Smart Climate 310 rev 03 Internal Switches Internal switches are located inside the auxiliary module...
Страница 96: ...96 Smart Climate 310 rev 03 Probe Assignment...
Страница 97: ...Smart Climate 310 rev 03 97 User Setup Menu...
Страница 98: ...98 Smart Climate 310 rev 03...
Страница 101: ...Smart Climate 310 rev 03 101 3 Press on the card and make it clip to the main board...
Страница 102: ...102 Smart Climate 310 rev 03...