CHAPTER 8 OPERATION INTRODUCTION
36
(2) Press SHIFT + A set keys to make it perform as OCP setting. The value can be adjustable by turning the
Encoder, and the last digit will be blinking. Press ENTER to confirm. The maximum adjustable value is 110% of
rated current and the adjustment will be limited by the current setting of the panel (No lower than the panel A
setting). Command: SOURce:CURRent:PROTection:LEVel
8-4. RECALL SETTING
(1) There are 16 memory-recalled settings. Under RECALL status, press RCL key to recall the memories. 16 sets of
memory can be recalled in sequence. MEMORY FLAG should be set to define the execute range when stored
memory sets are less than 16 sets.
(2) For safety operation, when you change the OVP/OCP value after storing some settings, the updated OVP/OCP
value should be higher than the stored setting. Once you have recalled the settings, the recalled value will not
be higher than the updated OVP/OCP value.
(3) When operating the RCL function, the output ON/OFF will remain at the last status.
(4) Press V set key to leave the RCL mode.
When the output is ON, after pressing RCL, the displays of voltage/current windows will be blinking at the first 3
seconds.
When the output is OFF, after pressing RCL, the displays of voltage/current windows will be blinking until the V set
key is pressed.
8-5. STORE SETTING
(1) The STORE function provides total 16 settings for users to save the memory. The STORE saves V set and A set
only, not includes the OVP and OCP.
(2) After pressing SHIFT+RCL keys, the V display will show a set number (01~16) and the A display will be blank.
Turn the Encoder to select the number of stored settings. Press ENTER to confirm and leave STORE mode.
8-6. SETTING MENU FOR OPTIONAL GPIB MODELS
(EQUIPPED WITH RS-485 & GPIB)
(1) Press SHIFT + ENTER keys to access MENU function.
(2) Turn the Encoder to select the functions of the MENU.
(3) After entering into MENU function, press ENTER to access the selected function and setting. Press ENTER to
confirm the change. Turn the Encoder to move forward for the next function/setting. Press SHIFT + ENTER keys
to leave the mode.