![GSi Protek PD Series Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/gsi/protek-pd-series/protek-pd-series_user-manual_2275134015.webp)
CHAPTER 4 REAR PANEL DESCRIPTION
15
4-2. REAR PANEL DESCRIPTION
4-2-1. The 3 pins pluggable terminal block, for connection of RS-485 interface:
When one set of DC power supply is remote controlled, through RS-
485 interface, a 1/4W 120Ω terminal resistor is
required. In general, a system that its connecting distance is less than 300m does not need to use the terminal
resistor. However, to avoid hav
ing interference, it is recommended to connect a 1/4W 120Ω terminal resistor
(connect to + and
– pin) at the last unit.
4-2-2. Digital programming Connector:
For GPIB remote control (Optional interface)
For LAN remote control (Standard interface)
LAN Status Indicator Color and States
State
Status
On
– Solid Green, steady illumination Normal Operation
On
– Flashing Green
Device Identify
Off
LAN Fault
4-2-3. Analog programming control port:
Please refer to < Chapter 5. ANALOG CONTROL> for functions
Isolated Analog Programming port (Optional)
Non-Isolated Analog Programming port (Standard)