2. Decal

Please remember, safety decals provide important safety information for people working near equipment 
that is in operation. If a safety sign cannot be easily read for any reason or has been painted over, replace 
it immediately. Additional safety signs may be obtained from your dealer, distributor or ordered from the 
factory free of charge.

Contact:

The GSI Group
1004 E. Illinois St.
Assumption, IL. 62510
Phone: 1-217-226-4421

Moving side plate. 
Auto equipment can
start at any time. 
Disconnect and lockout
before servicing. 

DC-1248

WARNING

GSI Group 217-226-4421

DC-1248
(Not to scale.)

Содержание PNEG-765

Страница 1: ...PNEG 765 In Line Intermediate Discharge Gates Installation Manual PNEG 765 Date 01 29 14...

Страница 2: ...2 PNEG 765 In Line Intermediate Discharge Gates...

Страница 3: ...nes 4 Safety Instructions 5 Chapter 2 Decal 7 Chapter 3 Installation 8 Overall Gate Dimensions 8 Cut Out Discharge Hole in Trough Bottom 9 Manual Gate Installation 10 Motor Driven Gate Installation 11...

Страница 4: ...ctions Failure to read this manual and its safety instructions is a misuse of the equipment and may lead to serious injury or death DANGER WARNING CAUTION NOTICE This is the safety alert symbol It is...

Страница 5: ...urisdiction should be consulted before installations are made Follow Safety Instructions Carefully read all safety messages in this manual and safety signs on your machine Keep signs in good condition...

Страница 6: ...rgency Equipment Quickly Accessible Wear Protective Clothing Wear close fitting clothing and safety equipment appropriate to the job Remove all jewelry Tie long hair up and back Wear safety glasses at...

Страница 7: ...ad for any reason or has been painted over replace it immediately Additional safety signs may be obtained from your dealer distributor or ordered from the factory free of charge Contact The GSI Group...

Страница 8: ...nsions Overall Gate Dimensions Conveyor Size A B C 0912 9 00 30 00 68 125 1212 12 00 30 00 68 125 1612 16 00 30 00 68 125 1214 12 00 30 00 68 125 1614 16 00 30 00 68 125 2114 21 00 30 00 68 125 1420 1...

Страница 9: ...red around the discharge location dimension D can be used as a reference 4 Mark the opening outline on the intermediate bottom and verify the size with the gate opening prior to cutting the material 5...

Страница 10: ...nd key way then tighten the set screw This gate can be operated by a chain cable or hand wheel See Figure 3C 2 Manual gates up to 16 wide are fitted with a single rack Manual gates larger than 16 wide...

Страница 11: ...s 11 Motor Driven Gate Installation Install Motor Bracket 1 Install the motor bracket to the gate Then attach the motor to the bracket as shown in Figure 3D using the provided hardware Figure 3D Ref D...

Страница 12: ...e securely fastened adjust lever arms so they come in contact with tripper blocks on underneath side of slide plate 4 Disconnect the power at the electrical panel and run the proper gauge electrical w...

Страница 13: ...charge Gates 13 Install Limit Switch Continued Figure 3G Figure 3H EXPLODED VIEW shown without side for clarity Ref Description Ref Description B Limit Switch E Side view with side removed clarity C A...

Страница 14: ...rmediate Discharge Gates Install Limit Switch Continued Figure 3I GATE CLOSED POSITION shown without side for clarity Figure 3J GATE OPENED POSITION shown without side for clarity Ref Description C Ac...

Страница 15: ...ng intermediate bottom holes or alternatively match drill the intermediate bottom flanges to existing gate flange slots Regardless of either method a maximum of 8 bolt spacing should be kept 3 Install...

Страница 16: ...ne Intermediate Discharge Gates 4 Wiring Diagram Typical Wiring Diagram OPEN CLOSE STOP REVERSING STARTER Remove internal jumpers 3 to 6 5 to 7 Open position switch Closed position switch Break for mo...

Страница 17: ...LAR PURPOSE OR DESIGN OF SUCH PRODUCTS GSI shall not be liable for any direct indirect incidental or consequential damages including without limitation loss of anticipated profits or benefits The sole...

Страница 18: ...e carefully followed in all cases Authorities having jurisdiction should be consulted before installations are made GSI Group 1004 E Illinois St Assumption IL 62510 0020 Phone 1 217 226 4421 Fax 1 217...