5. Warranty

GSI Group, LLC Limited Warranty

The GSI Group, LLC (“GSI”) warrants products which it manufactures to be free of defects in materials and workmanship 
under normal usage and conditions for a period of 12 months after sale to the original end-user or if a foreign sale, 
14 months from arrival at port of discharge, whichever is earlier. The end-user’s sole remedy (and GSI’s only obligation) 
is to repair or replace, at GSI’s option and expense, products that in GSI’s judgment, contain a material defect in materials 
or workmanship. Expenses incurred by or on behalf of the end-user without prior written authorization from the GSI 
Warranty Group shall be the sole responsibility of the end-user.

Warranty Extensions:

The Limited Warranty period is extended for the following products:

GSI further warrants that the portable and tower dryer frame and basket, excluding all auger and auger drive components, 
shall be free from defects in materials for a period of time beginning on the twelfth (12

th

) month from the date of purchase 

and continuing until the sixtieth (60

th

) month from the date of purchase (extended warranty period). During the extended 

warranty period, GSI will replace the frame or basket components that prove to be defective under normal conditions of 
use without charge, excluding the labor, transportation, and/or shipping costs incurred in the performance of this 
extended warranty.

Conditions and Limitations:

THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE LIMITED WARRANTY DESCRIPTION SET FORTH 
ABOVE. SPECIFICALLY, GSI MAKES NO FURTHER WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, 
INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR 
PURPOSE OR USE IN CONNECTION WITH: (I) PRODUCT MANUFACTURED OR SOLD BY GSI OR (II) ANY ADVICE, 
INSTRUCTION, RECOMMENDATION OR SUGGESTION PROVIDED BY AN AGENT, REPRESENTATIVE OR 
EMPLOYEE OF GSI REGARDING OR RELATED TO THE CONFIGURATION, INSTALLATION, LAYOUT, SUITABILITY 
FOR A PARTICULAR PURPOSE, OR DESIGN OF SUCH PRODUCTS.

GSI shall not be liable for any direct, indirect, incidental or consequential damages, including, without limitation, loss of 
anticipated profits or benefits. The sole and exclusive remedy is set forth in the Limited Warranty, which shall not exceed 
the amount paid for the product purchased. This warranty is not transferable and applies only to the original end-user. GSI 
shall have no obligation or responsibility for any representations or warranties made by or on behalf of any dealer, agent 
or distributor.

GSI assumes no responsibility for claims resulting from construction defects or unauthorized modifications to products 
which it manufactured. Modifications to products not specifically delineated in the manual accompanying the equipment at 
initial sale will void the Limited Warranty.

This Limited Warranty shall not extend to products or parts which have been damaged by negligent use, misuse, alteration, 
accident or which have been improperly/inadequately maintained. This Limited Warranty extends solely to products 
manufactured by GSI.

Prior to installation, the end-user has the responsibility to comply with federal, state and local codes which apply to the 
location and installation of products manufactured or sold by GSI.

Product

Warranty Period

AP Fans and Flooring

Performer Series Direct Drive Fan Motor

3 Years

* Warranty prorated from list price:

  0 to 3 years - no cost to end-user

  3 to 5 years - end-user pays 25%

  5 to 7 years - end-user pays 50%

  7 to 10 years - end-user pays 75%

** Warranty prorated from list price:

    0 to 3 years - no cost to end-user

    3 to 5 years - end-user pays 50%

† Motors, burner components 

and moving parts not included. 
Portable dryer screens included. 
Tower dryer screens not included.

All Fiberglass Housings

Lifetime

All Fiberglass Propellers

Lifetime

Cumberland 
Feeding/Watering 
Systems

Feeder System Pan Assemblies

5 Years **

Feed Tubes (1-3/4" and 2.00")

10 Years *

Centerless Augers

10 Years *

Watering Nipples

10 Years *

Grain Systems

Grain Bin Structural Design

5 Years 

Grain Systems
Farm Fans
Zimmerman

Portable and Tower Dryers

2 Years

Portable and Tower Dryer Frames and 
Internal Infrastructure †

5 Years

9101239_1_CR_rev7.DOC                                                                                                                                            (revised July 2009)

Содержание PNEG-1724

Страница 1: ...PNEG 1724 S2 Quick Start Guide Canister Installation Manual PNEG 1724 Date 07 21 10...

Страница 2: ...2 PNEG 1724 S2 Quick Start Guide Canister...

Страница 3: ...Start Guide Canister 3 Contents Chapter 1 Safety 4 Safety Guidelines 4 Safety Instructions 5 Operator Qualifications 9 Chapter 2 General Information 10 Chapter 3 Installation 11 Chapter 4 Parts List 1...

Страница 4: ...misuse of the equipment and may lead to serious injury or death This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this...

Страница 5: ...carefully followed in all cases Authorities having jurisdiction should be consulted before installations are made Follow Safety Instructions Carefully read all safety messages in this manual and safe...

Страница 6: ...ned in O S H A section 1910 147 where appropriate C Do not use this slip ring with electrical loads greater than the rated current and voltage D Information regarding the current and voltage rating of...

Страница 7: ...Wear gloves to protect your hands from sharp edges on plastic or steel parts Wear steel toe boots to help protect your feet from falling debris Tuck in any loose or dangling shoe strings A respirator...

Страница 8: ...ating this equipment NEVER allow any person intoxicated or under the influence of alcohol or drugs to operate the equipment Make sure someone is nearby who is aware of the proper shut down sequence in...

Страница 9: ...ion iii Unqualified or incompetent persons are to remain out of the work area iv O S H A Occupational Safety and Health Administration regulations state At the time of initial assignment and at least...

Страница 10: ...ation NEVER enter a grain bin unless ALL power driven equipment has been shut down Disconnect and lock out power before entering the bin or servicing the equipment ALWAYS keep ALL guards and shields i...

Страница 11: ...t allow the canister to be hidden or blocked during normal operations DO NOT USE the stiffener attachment holes to attach the canister The stiffener attachment holes are to be utilized for load bearin...

Страница 12: ...lts through the sidewall washer to the inside of the sidewall sheet through the two 2 brackets and fasten together with three 3 5 16 18 nylock nuts See Figure 3B Figure 3B 8 Attach the canister to the...

Страница 13: ...lace one of the quick start guides PNEG 1723 in the canister and replace the cap Make sure that the rubber gasket is inserted between the canister body and the canister cap The other guide should be p...

Страница 14: ...l Canister Assembly 1 2 GK80045 Canister Bracket 1 3 S 277 5 16 18 x 1 1 4 HH Bin Bolt w Washer YDP Grade 5 6 4 S 7382 5 16 18 Nylock Nut Zinc Grade 5 6 5 PNEG 1723 Series II Sweep Quick Start Guide P...

Страница 15: ...PURPOSE OR DESIGN OF SUCH PRODUCTS GSI shall not be liable for any direct indirect incidental or consequential damages including without limitation loss of anticipated profits or benefits The sole an...

Страница 16: ...regulations which should be carefully followed in all cases Authorities having jurisdiction should be consulted before installations are made GSI Group 1004 E Illinois St Assumption IL 62510 0020 Pho...

Отзывы: