Figure 6B
Setting the Timers
Setting the timers for the dryer is a simple procedure. To set the timers, touch the
button at
the bottom of Operation screen. A new screen will appear called the Select Timers to Modify screen.
As you can see there are five (5) timers that you can modify:
1.
Load delay:
This delay is used to delay the starting of the load conveyor when the dryer is unloading
to prevent the load conveyor from cycling to often.
2.
Out of grain (OOG) timer:
The OOG timer should be set to the maximum time it takes for the dryer
to refill. Note that the computer will display the time required to fill the dryer on the previous load
operation to aid you in setting an accurate time. If the dryer runs out of grain while the Load Auger
switch is in the AUTO position, the OOG timer automatically shuts off the dryer after the period of
time preset on the timer.
3.
Fan delay timer:
The fan sequence delay timer.
4.
Cool down timer:
The cool down timer is used to set the amount of time the fan is to run, after a
non-heat related shut down. Setting to 0 will cause an immediate shut down on a warning. The range
is from 0 to 20 minute.
5.
Unload delay timer:
The unload delay timer is used to control the amount of time the unload auger
runs after the metering system stops to allow the unload auger to clean itself out.
Содержание PNEG-1707
Страница 1: ...TM Series Tower Dryer Operation Manual PNEG 1707 Version 2 1 Date 09 22 20 PNEG 1707...
Страница 21: ...4 Dryer Installation PNEG 1707 TM Series Tower Dryer 21 Modular Base Layout Figure 4A...
Страница 22: ...4 Dryer Installation 22 PNEG 1707 TM Series Tower Dryer Central United States Foundation Plan Figure 4B...
Страница 23: ...4 Dryer Installation PNEG 1707 TM Series Tower Dryer 23 Northern United States Foundation Plan Figure 4C...