Chapter 6: Connecting the T/RH Cables
OPTION 1: Single Cable Connection
Connect a single T/RH cable to the cable connection port (28) in the Cable Monitoring Hub (16), using the
Dual Connector T/RH Extension Cable (23).
NOTE:
Make sure to secure the extension cable (23) every 3' by using P-clips.
Figure 6-1
Connecting a single T/RH cable to the Cable Monitoring Hub
16
Cable Monitoring Hub
28
Cable connection port
23
Dual Connector T/RH Extension Cable
44
PNEG-2347
Cable Monitoring System