7. Installation
68
PNEG-250
Hi-Lo and PRO-1 Pan Feeders
The shocker wire is to be installed in 50' (15.24 m) increments maximum.
4. Install an anti-roost wire tension spring, as shown in
at the next insulator, the fifth (5
th
)
auger tube down.
5. Hook one end of the spring over the insulator of the next section of wire as shown in
.
Figure 7DC
There should be 3/4" to 1" (1 cm to 2.5 cm) of stretch on the spring.
6. Cut the cable with enough slack to loop (D) the end of the cable through the spring and secure it with
a cable clamp sleeve (C).
Figure 7DD
7. Repeat the preceding steps of attaching sections of anti-roost wire until the control pan is reached.
8. Attach the anti-roost bracket onto the three (3) insulators onto the lid of the control pan as shown in
.
Figure 7DE
Ref #
Description
C
Cable Clamp Sleeve
D
Loop