![GSi 40-SERIES Скачать руководство пользователя страница 92](http://html1.mh-extra.com/html/gsi/40-series/40-series_construction-manual_2275090092.webp)
Attaching the Eave Angle to the Sidewall Sheet
The eave angle secures the bottom of the roof panels to the bin eave.
What You Should Know
Eave angles are bolted to the
inside
surface of the sidewall and will overlap each section.
1. Locate the top inside stiffener (B) and align the holes of the first eave angle (A) to the sidewall sheet
with the holes of the top inside stiffener (B).
IMPORTANT:
Make sure to align the center of the eave angle tab (C) a distance of
9.375 in
. from
the center of the top inside stiffener when assembling to the sidewall sheet. This is
very important to ensure the roof panels align properly with the rafters.
Figure 8-3
Eave angle alignment
A
First eave angle (CTR-0721)
C
Eave angle tab
B
Top inside stiffener
2. Install flange bolts (D) and flange nuts (B), leaving the end holes open.
NOTE:
The quantity of flange bolts (D) and flange nuts (B) may vary, depending on the sidewall
punch pattern.
3. Install the second eave angle (C) overlapping the first eave angle (A).
4. Install the flange bolts (D) and flange nuts (B), leaving the last hole open for the next eave angle to
be installed.
NOTE:
The quantity of flange bolts (D) and flange nuts (B) may vary, depending on the sidewall
punch pattern.
92
PNEG-4472
72 Ft Diameter Z-Tek Bins
Содержание 40-SERIES
Страница 6: ...NOTES 6 PNEG 4472 72 Ft Diameter Z Tek Bins ...
Страница 18: ...NOTES 18 PNEG 4472 72 Ft Diameter Z Tek Bins ...
Страница 26: ...NOTES 26 PNEG 4472 72 Ft Diameter Z Tek Bins ...
Страница 34: ...NOTES 34 PNEG 4472 72 Ft Diameter Z Tek Bins ...
Страница 72: ...NOTES 72 PNEG 4472 72 Ft Diameter Z Tek Bins ...
Страница 168: ...NOTES 168 PNEG 4472 72 Ft Diameter Z Tek Bins ...