NOTICE
Do not use a different battery than the one supplied with your system. See the
appendices for specifications.
WARNING
Do not use another kind of battery than the lead-acid batteries recommended by GSI
Electronics Inc. Although different technologies of lead-acid batteries are available
on the market, the use of other technologies can cause the controller to malfunction,
increase the risk of explosion, and increase the risk of fire.
WARNING
Use only the rechargeable type of recommended lead-acid batteries. The non-
rechargeable type of battery can cause the controller to malfunction, increases the
risk of explosion, and increases the risk of fire.
1. Run a 10 AWG cable of maximum 36 inches, from the battery enclosure to the main system enclo-
sure into cable glands to the bottom of each enclosure.
2. Connect one end of a cable to the negative terminal block VBAT - on the main board in the main
enclosure.
3. Connect the other end of the cable to the negative terminal BATTERY - in the battery enclosure.
4. Connect one end of the other cable to the positive terminal block VBAT + on the main board in the
main enclosure.
5. Connect the other end of the cable to the positive terminal B in the battery enclosure.
Connecting the Battery Temperature Sensor
1. Run a 20 AWG cable of maximum 36 inches from the battery enclosure to the main enclosure.
2. Connect one end of the cable to the negative terminal BAT TEMP - on the main board in the main
enclosure.
3. Connect the other end of the cable to the negative terminal TEMP - in the battery enclosure.
4. Connect one end of the other cable to the positive terminal BAT TEMP - on the main board in the
main enclosure.
5. Connect the other end of the cable to the positive terminal TEMP + in the battery enclosure.
Connecting a Sensor
A variety of different sensors can be hooked up to the system to monitor various inputs. The terminals
used for sensor inputs are numbered Z1, Z2, Z3, etc. on the main board.
What You Should Know
NOTE:
Sensors needing a DC supply have the possibility of two different supply outputs : 12Vdc output
and the 28 Vdc output.
The maximum voltage supplied to the 12 Vdc output is 12 VDC with a maximum current of 750
mA.
The maximum voltage supplied to the 28 Vdc output is 28 VDC with a maximum current of 350
mA.
Connect each sensor to a Z terminal and to the COM terminal.
28
895-00677
Agri Alert 128 Touch
Содержание 890-00584
Страница 14: ...NOTES 14 895 00677 Agri Alert 128 Touch...
Страница 20: ...NOTES 20 895 00677 Agri Alert 128 Touch...
Страница 30: ...NOTES 30 895 00677 Agri Alert 128 Touch...
Страница 38: ...NOTES 38 895 00677 Agri Alert 128 Touch...
Страница 44: ...NOTES 44 895 00677 Agri Alert 128 Touch...
Страница 64: ...Chapter 9 Configuring a 0 5 Volt Zone Type 64 895 00677 Agri Alert 128 Touch...
Страница 66: ...NOTES 66 895 00677 Agri Alert 128 Touch...
Страница 82: ...NOTES 82 895 00677 Agri Alert 128 Touch...
Страница 88: ...NOTES 88 895 00677 Agri Alert 128 Touch...
Страница 92: ...NOTES 92 895 00677 Agri Alert 128 Touch...
Страница 96: ...NOTES 96 895 00677 Agri Alert 128 Touch...
Страница 100: ...NOTES 100 895 00677 Agri Alert 128 Touch...
Страница 102: ...NOTES 102 895 00677 Agri Alert 128 Touch...
Страница 106: ...NOTES 106 895 00677 Agri Alert 128 Touch...
Страница 107: ...F Wiring Diagram with Terminals 895 00677 Agri Alert 128 Touch 107...
Страница 108: ...Appendix F Wiring Diagram with Terminals Wiring diagram with a DPST disconnect switch 108 895 00677 Agri Alert 128 Touch...
Страница 109: ...Appendix F Wiring Diagram with Terminals Wiring diagram with a SPST disconnect switch 895 00677 Agri Alert 128 Touch 109...
Страница 110: ...NOTES 110 895 00677 Agri Alert 128 Touch...
Страница 118: ......