background image

EN

Refs. 901622

User manual

w w w . g s e r t e l . c o m

HIGH PERFORMANCE PORTABLE METER INTENDED FOR PROFESSIONAL USERS

ADVANCED FEATURES AND HIGH MEASUREMENT ACCURACY

Содержание 901622

Страница 1: ...EN Refs 901622 User manual w w w g s e r t e l c o m HIGH PERFORMANCE PORTABLE METER INTENDED FOR PROFESSIONAL USERS ADVANCED FEATURES AND HIGH MEASUREMENT ACCURACY...

Страница 2: ......

Страница 3: ...p menu 17 Inputs Outputs 17 Powering 18 Settings 18 Main menu 21 1 Settings 21 2 User profiles 23 3 Optical attenuation 25 4 Satellite identification 25 5 LTE check 26 6 TV Analyser 27 7 Spectrum Anal...

Страница 4: ...the battery pack supplied by the manufacturer ref 901640 Safety requirements Product inspection Inspect the equipment for shipping damage Shouldanydamagebediscovered immediately file a claim with the...

Страница 5: ...le meter Intuitive Thanks to its novel interface designed to get the most out of its multi touch 8 screen All the information about the signal in one screen Mosaic feature with up to 6 user defined wi...

Страница 6: ...er supply Input 100 240V 50 60Hz Output 12VDC 4A Battery Li ion 7 2VDC 9000mAh Field replaceable Operating time 4 hours Operating temperature 5 C to 45 C 23 F a 104 F Storage temperature 20 C to 70 C...

Страница 7: ...e 42 1800MHz MPEG image Modulation 8VSB Power 90 20 dBm MER Up to 40dB PreBER 1 0E 2 1 0E 8 PostBER 1 0E 2 1 0E 9 Constellation MER by carrier Constellation Uncorrectedpackets TILT Attenuation Digital...

Страница 8: ...0 128dB V V A Up to 52dB C N Up to 30dB Features Up to 6 widgets user customizable System Scan with measurementsand learning plan LTEcheck 4Gand5G FO 40 7 dBm Reference 901622 GPS and Drive Test Optio...

Страница 9: ...oard 1 DeviceON OFFbutton Toturntheequipment off press and hold for approximately 3 seconds Short press to lock unlock the screen 2 Menu button First press features menu is shown Second press top menu...

Страница 10: ...ed the red light remains red A 1 hour charge will provide battery for around two working hours The charge management system will detect various conditions preventing charging such as a battery that is...

Страница 11: ...harged If the battery charge is less than 30 the light is red If the battery charge is between 30 and 60 the light is yellow If the battery charge is greater than 60 the light is green The battery pac...

Страница 12: ...ng The first time you turn your Hexylon on please follow the next steps for a proper registration To do that you must be registered on our website www gsertel com In addition you need internet connect...

Страница 13: ...be prompted to register your meter each time you turn it on Back back to previous step Indicates that your internet connection works well 3 2 If you select Wi Fi a list with all the Wi Fi networks wil...

Страница 14: ...channel list of channels add or remove channels Changeselectedservice itallowstheusertoselect any other service locked previously This feature shows a pop up window with all the services that the user...

Страница 15: ...nt See section 9 LOGs Creates a new directory to save the recording file Start recording List of the RF or TS recordings File name Selectable bandwidth 1953125 3906250 7812500 15625000 Hz Change tuned...

Страница 16: ...files in Web application Current feature Wi Fi Quality profile Time Headphones output enabled Equipment model Enabled input Battery state GPS Mute Ethernet connected Enabled input See section Inputs O...

Страница 17: ...tabs that will be explained below To select one of them the user must tap on the title Inputs Outputs Doing tap on the connector draw the corresponding input output will be enabled disabled Once it i...

Страница 18: ...ut please wait a few seconds until the HEXYLON detects the CAM Then you can access to the MMI menu of the CAM Select the file you want to play and tap on Start Powering Allows setup the preamplifiers...

Страница 19: ...doing drag Tap to select the parameter Increases Decreases doing drag Select parameter doing tap Touch increases decreases the sensitivity of the touch control Headphones enables disables audio A V ou...

Страница 20: ...er selects the DHCP mode DHCP ON the network parameters will be configured automatically If the DHCP mode is off the user must type all the network parameters IP gateway Mask and DNS and the do tap in...

Страница 21: ...the following sections 1 Settings Allows set all the global parameters of the meter This feature has several tabs that will be explained below 1 1 Regional Sets the language the date and the time 1 2...

Страница 22: ...le in an USB stick and insert the USB stick into the USB connector of your HEXYLON A message appears automatically indicating that an update is available on the USB When you go to the Update menu the...

Страница 23: ...g feature of the main menu see section 1 Settings 2 2 Add Adds a new user profile When you tap on this button a popup window will open where the user must set all the required parameters First of all...

Страница 24: ...the list If you include the satellite band in the profile you must select how many satellites you want to include in that profile Then you must set all the parameters for each one Each satellite plan...

Страница 25: ...sents the attenuation of each wavelength Enabled O F input icon Calibrate select the wavelength tap on the graphic or on the list and tap on this button to calibrate it Units mW uW dBm Auto lambda OPS...

Страница 26: ...nds are analysed You must display the Options Context Menu to analyse the 5G band 4 2 Options context menu Powering VDC Selects the preamplifier powering DiSEqC only satellite band selects the DiSEqC...

Страница 27: ...as well as the 5G up and down links detecting possible interfering signals and if it is necessary it recommends a filter Powering VDC Selects the preamplifier powering 6 TV Analyser This is the main f...

Страница 28: ...ble this option when the outlet in your installation has both terrestrial and satellite bands So both bands will be scanned consecutively If this options is disabled only the selected band will be sca...

Страница 29: ...re and connect the meter taking care to have this function ON The Hexylon will measure the levels of all the channels comparing them with the reference ones When this option is ON the bars of the grap...

Страница 30: ...ng VDC Selects the preamplifier powering DiSEqC only satellite band selects the DiSEqC parameter Sat A Sat B Sat C Sat D Positioner only satellite band makes it possible to control the DiSEqC motors u...

Страница 31: ...attenuation Quality profile allows to select the quality profile Powering VDC Selects the preamplifier powering DiSEqC only satellite band selects the DiSEqC parameter Sat A Sat B Sat C Sat D Position...

Страница 32: ...cted only Television and Services features will be available 6 4 1 Television This feature allows to visualize the selected service image of the tuned channel Note When the image is not available one...

Страница 33: ...parameters of the locked signal Distribution and bitrates of the service PIDs Graph with the distribution of the channels services List of services with ID the service name PSIP and bitrates The color...

Страница 34: ...he slot with the meter parameters frequency band powering and DiSEqC In addition a SCR icon will be shown in the bar at the top SCR3 to indicate that the slot is enabled While the slot is enabled all...

Страница 35: ...tune into the slot frequency 1210MHz and will set the slot with the meter parameters frequency band powering and DiSEqC In addition a SCR icon will be shown in the bar at the top SCR3 to indicate that...

Страница 36: ...the number of traces to average Standard Selects the standard of the signal BW Selects the bandwith Advanced Access to spectrum advanced features Hold enables disables max hold y min hold features Ta...

Страница 37: ...erence level manually as well as to select the span to include a frequency range wide enough The audible signal becomes continuous when the signal level is close to the reference level Then it is nece...

Страница 38: ...ntenna that has been previously stored SCR only satellite band Selects the SCR parameters multiswitch standard and slots When a slot is enabled for example slot 3 freq 1210MHz the meter will tune into...

Страница 39: ...ne of the 8 positions for the antenna that has been previously stored SCR only satellite band Selects the SCR parameters multiswitch standard and slots When a slot is enabled for example slot 3 freq 1...

Страница 40: ...y the user 6 4 9 1 Main window ESR Errored Second Ratio Number of erroneous seconds within an observation window of the past 20 seconds Total analysis Start and end time of the analysis and number of...

Страница 41: ...click corresponds to one step in the movement of the motor pitch motors By holding the key down successive movement sequences will be executed until the key is released Store 8 storage positions are...

Страница 42: ...nna will be stored Goto recovers one of the 8 positions for the antenna that has been previously stored SCR only satellite band Selects the SCR parameters multiswitch standard and slots When a slot is...

Страница 43: ...3 freq 1210MHz the meter will tune into the slot frequency 1210MHz and will set the slot with the meter parameters frequency band powering and DiSEqC In addition a SCR icon will be shown in the bar at...

Страница 44: ...re the current position of the antenna will be stored Goto recovers one of the 8 positions for the antenna that has been previously stored SCR only satellite band Selects the SCR parameters multiswitc...

Страница 45: ...nel parameters IP measurements History of the measurements during an interval selected by the user Drag to move the blue mark Clear clears the graph Last 10 min hour 1hour day 1 day 1 week Allows sele...

Страница 46: ...st of events Tap to select Selected service is displayed in light blue 7 Spectrum Analyser This feature has two screens spectrum analyser and waterfall Long swipe to switch between them 7 1 Spectrum a...

Страница 47: ...ces to average Standard Selects the standard of the signal BW Selects the bandwith Advanced Access to spectrum advanced features Hold enables disables max hold y min hold features Tapping on Clear but...

Страница 48: ...the signal level is close to the reference level Then it is necessary to increase the reference level to get a more accurate adjustment This is a useful feature to point antennas without having to loo...

Страница 49: ...spectrum options context menu see section 7 1 Spectrum analyser 8 Radio Analyser This feature is similar to TV Analysis in the radio band So it has two screens scan and mosaic 3 1 Long swipe to switch...

Страница 50: ...nly the selected band will be scanned Note Note that if the selected user profile does not allow to make measurements in some bands the scan will not be done in that band Show all ON OFF When show all...

Страница 51: ...t shows power or level and C N In addition a green trace is shown in the spectrum This trace indicates the levels in the reference point Quality profile allows to select the quality profile Powering V...

Страница 52: ...equencies and radio text 8 4 1 1 Main Window 8 4 2 Parameters This feature shows the parameters of the locked signal 8 4 2 1 Main Window 8 3 1 Main window All the available features are explained in s...

Страница 53: ...ers 8 4 4 2 Options context menu Clear restarts the graph Last 5 min hour day 1 day 1 week Allows select the time interval shown in the graph Restart Att restarts the control attenuation Quality profi...

Страница 54: ...ger enables disables the trigger by level feature To select the level tap on the label and a popup keyboard appears Fill enables disables the spectrum graph filled Quality profile allows to select the...

Страница 55: ...grey shadow indicates the maximum deviation value to make sure there are no problems in neighbouring channels Chart represents the distribution of the frequency deviation 1 minute to 2 hours List of F...

Страница 56: ...lute shows deviation absolute values in the graphic 0 150 kHz Hide hides no relevant measurements to deviation measurement 8 4 13 MPX Spectrum Option 901633 This feature shows the spectrum of the demo...

Страница 57: ...s are user configurable 9 1 Main window 9 2 Features This section explains all the features available to The rectangular widget shows the channel map feature Tap on the top bar to select the widget fe...

Страница 58: ...ove the blue marker Status and level measurement Wi Fi network parameters 9 2 3 1 Main window 10 2 3 2 Contextual options menu Clear resets the graph Last 10 min hour day 1 day 1 week Allows select th...

Страница 59: ...en corresponding to this feature is Mosaic4 type This configuration has 4 widgets All the widgets are user configurable 10 1 Main window 10 2 Features This section explains all the features available...

Страница 60: ...s stopped Green icon if the ping is running Red icon if the conection to the server can not be established Tap to Start Stop the ping 10 2 2 1 Main window 10 2 3 NMAP Scan The NMAP Network Mapper Scan...

Страница 61: ...elected channel plan so you can select those that you want to check in the drive test Pause Run the test Stop the test Tap on the top bar to select the widget feature Double tap to see the feature scr...

Страница 62: ...will be the minimum necessary to perform the measurements in all the selected channels 11 2 Features This section explains all the features available to visualize in Drive Test function 11 2 1 Status...

Страница 63: ...locked Green icon if the GPS is locked Red icon if the GPS is unlocked List of measurements List of signal parameters 11 2 4 Evolution This function shows the time evolution of the selected channel m...

Страница 64: ...memory 12 LOGS The Hexylon saves two types of measurements files LOGs and MacroLOGs A LOG saves all the measurements in the screen as well as a screenshot To save a LOG tap on the icon in the bottom b...

Страница 65: ...IP of your meter in the address bar of your web browser Chrome recommended To know the IP of your meter you must access to the top menu and select Network feature see section Settings in Top menu Thef...

Страница 66: ...lete LOG Select LOG If the MacroLOG has GPS information you can see all the measurements iterations placed in a map in the position where they was made so you have a detailed mapping and coverage anal...

Страница 67: ...s Download file List of RF files Delete selected files 4 Plans In this window you can see all the channel plans of your Hexylon They are grouped in several categories Terrestrial Satellite Custom and...

Страница 68: ...at it is a streaming file indicated that the next field is the channel name in this case Das Erste HD If there is no name for a channel a default name will be assigned At last it must appear the proto...

Страница 69: ...create an IPTV channel list using the feature IPTV The meter has an IPTV channel named DEFAULT but it can be edited or deleted Display to see the channels Select the plans you want to save in your met...

Страница 70: ...the Display to see all the values Duplicate quality profile Display to see all the values Save the profile in the meter Delete profile Duplicate profile band or bands that he or she wants to use in th...

Страница 71: ...his functionality allows the user to have a replica of your meter in the cloud Each time the HEXYLON is connected to the internet the data in the cloud and the data in the Hexylon will be synchronized...

Страница 72: ...er to the external power source LOW BATTERY Shutting down Some time after the LOW BATTERY message appears time varies depending on the functions used it will appear this message If the meter is not co...

Страница 73: ...port for repair read the manual to ensure proper use and attempt to RESET the unit to clear any problems Repair service Do not return the unit without first contacting Gsertel Technical Support If the...

Страница 74: ...de reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not install...

Страница 75: ...exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 L appareil ne doit pas produire de brouillage et 2 L utilisateur de l appareil doit accepter tout brouillage radio lect...

Страница 76: ...Hexylon High performance portable meter 76...

Страница 77: ......

Страница 78: ...901622_1 38_EN...

Отзывы: