24 / 56 EN
Split-type room air conditioner / Installation Manual
Step 7: Wrap piping and cables
Before passing the piping, drain hose, and the signal cable through the wall hole, you must bundle
them together to save space, protect them, and insulate them.
1. Bundle the drain hose, refrigerant pipes, and signal cable according to Fig. 5.10.
Indoor Unit
Space behind unit
Refrigerant piping
Insulation tape
Signal wire
Drain hose
Fig. 5.10
Drain hose must be on bottom
Make sure that the drain hose is at the bottom of the bundle. Putting the drain hose at the top of the
bundle can cause the drain pan to overflow, which can lead to fire or water damage.
Do not intertwine signal cable with other wires
While bundling these items together, do not intertwine or cross the signal cable with any other wiring.
2. Using adhesive vinyl tape, attach the drain hose to the underside of the refrigerant pipes.
3. Using insulation tape, wrap the signal wire, refrigerant pipes, and drain hose tightly together.
Double-check that all items are bundled in accordance with Fig. 5.10.
Do not wrap ends of piping
When wrapping the bundle, keep the ends of the piping unwrapped. You need to access them to test
for leaks at the end of the installation process (refer to Electrical Checks and Leak Checks section of
this manual).
Step 8: Mount indoor unit
If you installed new connective piping to the outdoor unit, do the following:
1. If you have already passed the refrigerant piping through the hole in the wall, proceed to Step 4.
2. Otherwise, double-check that the ends of the refrigerant pipes are sealed to prevent dirt or foreign
materials from entering the pipes.
3. Slowly pass the wrapped bundle of refrigerant pipes, drain hose, and signal wire through the hole in
the wall.
5
Indoor unit installation
Содержание GIN 090
Страница 53: ......
Страница 54: ......
Страница 55: ......
Страница 56: ......
Страница 57: ...Inverter Air Conditioner Manual GIN 090 GIN 091 GIN 120 GIN 121 GIN 180 GIN 181 GIN 240 GIN 241 RO Installation...
Страница 109: ......
Страница 110: ......
Страница 111: ......
Страница 112: ......
Страница 113: ...Inverter Air Conditioner Owner s Manual GIN 090 GIN 091 GIN 120 GIN 121 GIN 180 GIN 181 GIN 240 GIN 241...
Страница 124: ...12 28 EN Split type room air conditioner User Manual Deflector rod Fig B 2 Unit specifications and features...
Страница 139: ...Manufactured by Arcelik A S Karaagac Cd No 2 6 34445 Sutluce Beyoglu Istanbul Turkey...
Страница 140: ......
Страница 141: ...Inverter Air Conditioner Owner s Manual GIN 090 GIN 091 GIN 120 GIN 121 GIN 180 GIN 181 GIN 240 GIN 241 RO...
Страница 167: ...Fabricat de Arcelik A S Karaagac Cd No 2 6 34445 Sutluce Beyoglu Istanbul Turcia...
Страница 168: ......