Страница 1: ...BEKO 2014 BETTER T TYPE HOOD SERVICE MANUAL...

Страница 2: ...IN THE LABELS 24 7 2 PRODUCTS USED TAGS AND DESCR PTIONS 24 7 2 1 Type of Label 24 7 2 2 Barcode Label 25 7 3 3 Enercy Label 25 8 GENERAL WORKING PRINCIPLE 26 9 LIST OF COMPONENT COMPONENT OPERATION...

Страница 3: ...12 7 MAINS CORD REPLACEMENT HOODS 38 12 8 INSTALL NG A CARBON FILTER 40...

Страница 4: ...ch are released as a result of burning will be drawn back into the house through chimney draught Do not operate the appliance together with sources that may emit toxic gasses and create air draught wo...

Страница 5: ...OR SAFETY Supply cord do not pass over from hot surface during the installation As a result of melting of cable produck could do short ciircuit and it could cause a fire During the installation be car...

Страница 6: ...curtains If Cleaning do not do suitable periodic time risk of burns can occur on your hood Kitchen air from the vapors of cooking odors and good for cleaning cooking or baking business run more than...

Страница 7: ...cy 220 240 V 50 Hz Control 3 seviye Suction power 620 m3 h Motor power consumption 150KW Lamp power consumption 25KW Total power consumption Max 221 W Fuse min 10 A Air outlet pipe diameter 120 mm Spe...

Страница 8: ...ss Against any product changes state product package should open not to damage product or package Product should be carried by two person for safety of the product and ergonomics While downloading the...

Страница 9: ...HOOD 9 Chimney is avaible in the carton box seperated another carton Grasp with both arms and remove hood from inside the box Unpack hood Remove the left and right styrofoam...

Страница 10: ...product packaging Preserve from damp Fragile Carry with barrow in this way Do not carry the product like in the picture Carry the product in this way by squeezing with clamp Do not step on the product...

Страница 11: ...ectrical connection Manufactured with 2 track power cable this device must be connected to the mains by an electrical switch with at least 3mm clearance between bipolar contact leads Have a qualified...

Страница 12: ...lines at 90mm distance on both sides of the axis line reaching to the ceiling Then determine hole locations by drawing the lines Y J X2 and X1 that cut vertically the axis line for which measurements...

Страница 13: ...distance ring and pull downward to make sure that it is secured Then screw the body onto the wall from the holes J1 and J2 on the upper back of the body To avoid the hood falling down accidentally for...

Страница 14: ...nsidered that sharp corners and sudden contractions will have a negative impact on air suction The hood must never be connected to a chimney to which another device was already connected NOTE Connecti...

Страница 15: ...iodically and failure to replace carbon filters at the end of service life approximately 4 months may have the risk of causing fire 7 Installation of chimney To install upper chimney A secure the uppe...

Страница 16: ...llow the air easily going out of the room in horizontal arrangements the pipe should be slightly tilted upwards approximately 10 NOTE If the carbon filter is installed on your hood it must be removed...

Страница 17: ...llations should be considered the following values associated with the product External dimensions height width depth min 735 mm max 1130 mm 600 mm 502 mm Voltage frequency 220 240 V 50 Hz Control 3 s...

Страница 18: ...HOOD 18 Install the product s plug to wattmeter and install wattmeter s plug to wall plug Select the programme you want to measure the hood 1 step 2 step 3 step update...

Страница 19: ...data should be same as product type label s data Type label located to inside the product at the next to the fan engine After the product installation the plug must be at easily accessible location 1...

Страница 20: ...tings For a good performance low speed is recommended in normal conditions and high speed for heavy smell and steam conditions 1 Open Close Hz1 2 Speed 2 3 Speed 3 Booster 4 Function knob 5 Lamp Butto...

Страница 21: ...speed will be activated 6 2 Closing the Hood 6 3 Running Lamp 6 4 Light off To change the speed level press the speed2 and Speed3 button The hood is running at a certain speed press the Power button...

Страница 22: ...0 minutes work Continues to work in the speed3 position will active at the end of 10 minutes Air cleaning mode Closing the air cleaning mode Air cleaning mode is activated The warning lamp 6 flashes i...

Страница 23: ...ut off mode is activated and level warning light flashes in the color set that level The product automatically turns off after 20 minutes at the set level While the roduct running a certain level pres...

Страница 24: ...7 2 Products used tags and descript ons 7 2 1 Type of Label It contains some information about the product Type tag location Type of products type label located to next to engine You should remove pr...

Страница 25: ...arcode label includes many lines and spaces which represent producer country brand and feature of model Location of barcode label This label bonded at product packing s carton 7 3 3 Enercy Label There...

Страница 26: ...on The other 4 buttons for motor control There are 3 leves in the hood there is a one button for controlling each level and on off button Levels are shown as 1 2 3 Listed according to the suction powe...

Страница 27: ...152730004 HOOD FLUE ADAPTER The lamp controled by cummutotor is connected to the control button or with the help of a special button Air is filtered through the carbon filter and is sent back into th...

Страница 28: ...Adapter 152730004 HOOD FLUE ADAPTER The center hosts and apply on all processing units Air is filtered through the carbon filter and is sent back into the room again carbon filter to be mounted chimne...

Страница 29: ...HOOD 29 10 FLOW FAULT FAULT DETECTION DIAGRAMS...

Страница 30: ...HOOD 30 11 Component Assembly Disassembly of the equipment to be used in Cordless screwdriver...

Страница 31: ...Sheet Replacement 1 Chimney top sheet s right and left located a screw unscrewed by screwdriver 2 You can change unassembled chimney sheet Chimney of Hoods Replacement To change chimney firstly hood s...

Страница 32: ...HOOD 32 TR 2 You can change the filter with a new one Hoods Replacement Lamp Lamp light pressing turned clockwise direction Replace the lamp with a new one...

Страница 33: ...p Remove the screws to for replace the lamps sheet 3 Before removing the lamp lights remove sheet 2 Idle lamp sheet can replace it with a new sheet 12 2 Hoods Motor Replacement Hoods engine located wi...

Страница 34: ...HOOD 34 TR When removing the screws prevent the fall of the engine seen in the picture 5 After dismantling the screw slowly wasted away through the hood the engine can replace it with new...

Страница 35: ...HOOD 35 TR 12 3 Changing the hour intervals Plastic Sheet and plastic bound with 2 screws Remove the screw with the star screwdriver...

Страница 36: ...HOOD 36 TR 12 4 Replacing the motherboard Hoods Hood motherboard is attached to the chassis with 2 screws Remove the screws with a screwdriver help...

Страница 37: ...e the cover after the disassembly Remove the cable connections Remove the screws with a screwdriver help Replace the card with a new one 12 5 Changing Keys Push the button to the right to push the nai...

Страница 38: ...onnected to the chassis with 2 screws Disconnect the cables on the card respectively After disassembly replace with a new one 12 7 Hoods Supply Cord Replacement Hoods supply cord as shown in the pictu...

Страница 39: ...HOOD 39 TR 2 Unscrew the screws with a screwdriver supply cord holder can change 3 Hood cord plug from the mains plug holes spend your interests...

Страница 40: ...HOOD 40 TR 12 8 Installing a carbon filter The carbon filter is installed to slots are shown in the picture Place the carbon filter to the slots...

Страница 41: ...ed aluminum filter insert again NOTE Can be supplied from stock numbers in the order given by Carbon Filter of service to customer demands 165730006 CARBON F LTER 152730004 HOOD FLUE ADAPTER Place on...