6. Operation

6.1 Priming

• The Grundfos Type VLSE in-line centrifugal pumps are not self 

priming, and must be completely primed (filled with liquid) 
before starting.

• If the pump will operate with a positive suction head, prime by 

opening the suction valve and allowing liquid to enter pump 
casing.

• Open all air vents a the high points of pump and piping to 

ensure air is forced from pump by liquid.

• Disconnect the recirculation line at the seal housing and bleed 

completely of all air.

• Re-connect the line prior to start-up.
• Rotate the shaft by hand to free entrapped air from impeller 

passageways.

• If pump has a suction lift, priming must be accomplished by 

other methods.

• The use of foot valves or ejectors, or manual filling of the 

pump casing and suction line with liquid are possible methods 
suggested for this purpose.

6.2 Pre-start checklist

Make the following inspections before starting your Grundfos 
Type VLSE pump:
1. Make sure all wiring connections to the motor (and starting 

device) match the wiring diagram and produce

 clockwise

rotation as viewed from the end of the motor.

2. If the motor has been in storage for an extended length of 

time, either before or after installation, refer to motor 
instructions before starting. 

3. Check voltage, phase, and line circuit frequency with the 

motor data plate.

4. Turn rotating element by hand to make sure it rotates freely.
5. Tighten plugs in gauge and drain taps. If pump is fitted with 

pressure gauges, keep gauge cocks closed when not in use.

6. Check suction and discharge piping for leaks, and make sure 

all flange bolts are securely tightened.

6.3 Motor rotation

6.4 Starting the pump

1. Install coupling guard on split coupled units.
2. Fully open gate valve (if any) in suction line, and close gate 

valve in discharge line.

3. Fill suction line with liquid and completely prime pump.
4. Start the motor (pump).
5. Immediately make a visual check of pump and suction piping 

for pressure leaks.

6. Immediately after pump reaches full operating speed, slowly 

open the discharge gate valve until complete system flow is 
achieved.

7. Check discharge piping for pressure leaks.
8. If pump is fitted with pressure gauges, open gauge cocks and 

record pressure reading for future reference. Verify that the 
pump is performing in accordance with parameters specified 
on performance curve.

9. Check and record voltage, amperage per phase, and 

kilowatts, if a wattmeter is available.

6.5 Voltage regulation

The motor will operate satisfactorily under the following 
conditions for voltage and frequency variation, but not necessarily 
in accordance with the standards established for operation under 
rated conditions: The voltage variation may not exceed 10 % 
above or below rating specified on the motor data plate. 
The frequency variation may not exceed 5 % above or below 
motor rating. The sum of the voltage and frequency variations 
may not exceed 10 % above or below motor rating, provided the 
frequency variation does not exceed 5 %.

6.6 Pump shutdown

The following shutdown procedures will apply in most normal 
shutdowns for Grundfos Type VLSE pump. If pump will be 
inoperative for an extended length of time, follow storage 
procedures in Section IC. Always close the discharge gate valve 
before stopping pump. Close valve slowly to prevent hydraulic 
shock. Cut power to motor.

6.7 Short duration shutdown

For overnight or temporary shutdown periods under nonfreezing 
conditions, the pump may remain filled with liquid. Make sure the 
pump is fully primed before restarting. For short or frequent 
shutdown periods under freezing conditions, keep fluid moving 
within pump casing and insulate or heat pump exterior to prevent 
freezing.

6.8 Extended period shutdown

For long shutdown periods, or to isolate the pump for 
maintenance, lock-out power to pump and close suction gate 
valve. If no suction valve is used and the pump has positive 
suction head, drain all liquid from suction line to terminate liquid 
flow into pump suction nozzle. Remove plugs in pump drain and 
vent taps, as required, and drain all liquid from the pump volute 
casing. If freezing conditions will exist during long shutdown 
periods, completely drain the pump and blow out all liquid 
passages and pockets with compressed air. Freezing of pump 
liquid can also be prevented by filling the pump with antifreeze 
solution.

&DXWLRQ

Never run the pump dry in the hope that it will 
prime itself! Serious damage to the mechanical 
seal will result.

Warning
In the interest of operator safety, the unit must 
not be operated above the nameplate conditions. 
Such operation could result in unit failure 
causing injury to operating personnel. 
Consult instruction book for proper operation 
and maintenance of the pump and its supporting 
components.

&DXWLRQ

Verify driver rotation prior to startup and 
operation. Failure to do so can result in serious 
damage to pump and driver if rotation is wrong.

Содержание VLSE

Страница 1: ...GRUNDFOS INSTRUCTIONS VLSE Vertical in line split coupled pumps with integrated VFD Installation and operating instructions...

Страница 2: ...Table of contents 2 VLSE Pump Information 3 Motor information 12...

Страница 3: ...8 Extended period shutdown 7 7 Maintenance 8 7 1 Motor lubrication 8 8 Disassembly 8 8 1 Preparation for disassembly 8 8 2 Seal replacement VLSE 8 8 3 Wear ring replacement 9 8 4 Reassembly of pumps...

Страница 4: ...e other rights which vary from jurisdiction to jurisdiction 4 Installation mechanical Read these instructions thoroughly before installing and operating your Grundfos Type VLSE Vertical In line Centri...

Страница 5: ...to support the weight of pump and piping full of liquid and shall be designed to eliminate transmission of noise or vibration Grundfos Type VLSE In line pumps are designed to be mounted in horizontal...

Страница 6: ...ke packing mechanical seals require no field adjustments Observe the following precautions to avoid seal damage and obtain maximum seal life Do not exceed temperature or pressure limitations for the m...

Страница 7: ...nd record voltage amperage per phase and kilowatts if a wattmeter is available 6 5 Voltage regulation The motor will operate satisfactorily under the following conditions for voltage and frequency var...

Страница 8: ...ting motion as necessary to loosen bellows from shaft 7 Remove and discard seal spring and retainer 8 remove and discard seal seat from seal cap 2N and thoroughly clean the inside cavity of seal cap 9...

Страница 9: ...tment to their customers continues through an extensive service organization Highly trained technicians can assist customers with initial startup troubleshooting repair and system analysis Grundfos ma...

Страница 10: ...4A Case wear ring 20J Cast iron stand 4F Balance ring 21A Motor bracket 6A Pump shaft 22A Seal cap studs 8B Volute screw 23D Coupling halves 8C Pump shaft screw 24H Bushing 8E Coupling screw 34B Impe...

Страница 11: ...of internal gasket failure 27 There may be a misalignment of the pump shaft 28 The shaft may chatter because it is bent 29 The pump may run rough due to improper balancing of the impeller 30 The shaft...

Страница 12: ...mation 13 General description 12 13 1 Pumps without factory fitted sensor 12 13 2 Pumps with pressure sensor 12 13 3 Settings 12 14 Mechanical installation 13 14 1 Motor cooling 13 14 2 Outdoor instal...

Страница 13: ...fuse sizes see section 30 1 Supply voltage on page 41 15 1 4 Additional protection If the pump is connected to an electric installation where an ground leakage circuit breaker ELCB is used as addition...

Страница 14: ...power supply 15 1 9 Connections As a precaution the wires to be connected to the following connection groups must be separated from each other by reinforced insulation in their entire lengths Group 1...

Страница 15: ...box Fig 10 Connection of two protective ground leads using two of the leads of a 5 core power supply cable Protective ground leads must always have a yellow green PE or yellow green blue PEN color mar...

Страница 16: ...advertently pulled out of the cable entry Fig 11 Power connection Cable glands Cable glands comply with EN 50626 1 x M40 cable gland 1 x M20 cable gland 2 x M16 cable gland 2 x M16 knock out cable ent...

Страница 17: ...cable with screen and wire connection Always tighten screws for frame connections whether a cable is fitted or not Make the wires in the pump terminal box as short as possible 15 4 E pump electrical...

Страница 18: ...lled in accordance with Grundfos printed installation and operating instructions Splicing of the supplied cable would void any warranty 15 4 3 Connection of E pump to LiqTecp Fig 15 Connection of E pu...

Страница 19: ...mperature sensor in which case the description would be constant temperature in control mode controlled 16 2 Operating mode When the operating mode is set to Normal the control mode can be set to cont...

Страница 20: ...t value corresponds to 50 of the sensor measuring range see sensor nameplate 18 Setting by means of control panel Proportional pressure The pump head is reduced at decreasing water demand and increase...

Страница 21: ...light fields 5 and 6 are activated indicating a desired setpoint of 43 psi 3 bar The setting range is equal to the sensor measuring range see sensor nameplate Fig 25 Setpoint set to 3 bar pressure co...

Страница 22: ...19 3 4 3 19 3 9 1 19 1 4 19 2 5 19 3 4 1 2 19 3 10 19 2 6 19 3 4 2 2 19 3 11 1 19 1 4 1 19 2 7 2 19 3 5 19 3 12 19 2 8 2 19 3 6 19 3 13 1 19 2 9 1 19 3 7 19 3 14 1 19 3 7 19 3 15 1 1 This display only...

Страница 23: ...ing Bus control To override bus communication disconnect the bus connection See fig 36 on page 33 19 1 2 Operating mode Set one of the following operating modes Normal duty Stop Min Max The operating...

Страница 24: ...power supply since the fault occurred 30 min 19 2 Menu STATUS The displays appearing in this menu are status displays only It is not possible to change or set values The displayed values are the value...

Страница 25: ...Time till replacement of motor bearings When the motor bearings have been relubricated a prescribed number of times stored in the controller the display in section 19 2 8 Time till relubrication of m...

Страница 26: ...ules of thumb If the controller is too slow reacting increase Kp If the controller is hunting or unstable dampen the system by reducing Kp or increasing Ti 19 3 3 External setpoint The input for exter...

Страница 27: ...ult When the input is activated a timer will be started If the input is activated for more than 5 seconds the pump will be stopped and a fault will be indicated If the input is deactivated for more th...

Страница 28: ...he pump will return to continuous operation at constant pressure 2 If the flow is still lower than the low flow limit the pump will continue in start stop operation It will continue in start stop oper...

Страница 29: ...or the tank size is smaller than recommended select Low If a higher flow than normal is wanted or a large tank is used set the limit to High The value Custom can be seen in R100 but it can only be se...

Страница 30: ...gland into each MLE terminal box with a crescent wrench See fig 32 c Loosen the new cable gland caps and push the cable ends through the cable glands and into MLE motors d Remove the AYB connector plu...

Страница 31: ...d Nothing done When the bearing monitoring function is Active the controller will give a warning indication when the motor bearings are due to be relubricated or replaced See section 19 1 3 Fault indi...

Страница 32: ...3 2 19 3 7 19 1 3 19 2 3 19 3 3 19 3 8 19 1 3 1 19 2 4 19 3 4 1 2 19 3 9 1 19 2 5 19 3 4 2 2 19 3 10 19 2 6 19 3 5 19 3 11 1 19 2 7 2 19 3 6 19 3 12 19 2 8 2 19 3 7 19 3 13 1 19 3 14 1 19 3 15 1 1 Th...

Страница 33: ...2 19 3 7 19 1 3 19 2 3 19 3 3 19 3 8 19 1 3 1 19 2 4 19 3 4 1 2 19 3 9 1 19 2 5 19 3 4 2 2 19 3 10 19 2 6 19 3 5 19 3 11 1 19 2 7 2 19 3 6 19 3 12 19 2 8 2 19 3 7 19 3 13 1 19 3 14 1 19 3 15 1 1 This...

Страница 34: ...iPod touch 5G or iPhone 5 2 Grundfos MI 301 Separate module enabling radio or infrared communication The module can be used in conjunction with an Android or iOS based Smartphone with Bluetooth connec...

Страница 35: ...nel or R100 can only set the E pump to operating mode Stop Priority of settings with bus communication Example If the E pump is operating according to a setpoint set via bus communication the control...

Страница 36: ...psi and an external setpoint of 80 an 8 V analog signal to Terminal 4 if using an analog signal of 0 10 V the actual setpoint will be as follows In control mode uncontrolled the setpoint can be set ex...

Страница 37: ...for further details 25 Other bus standards Grundfos offers various bus solutions with communication according to other standards Contact Grundfos for further details 26 Indicator lights and signal rel...

Страница 38: ...ecause of a Fault Alarm or is running with a Warning or Relubricate indication If the pump was stopped restarting will be attempted it may be necessary to restart the pump by resetting the Fault indic...

Страница 39: ...from the terminal box 3 Connect the leads as shown in fig 43 Fig 43 How to switch an E pump from normal operation to emergency operation Use the screws from the power supply terminals and the nuts fro...

Страница 40: ...Grundfos company for assistance 29 5 Service parts and service kits For further information on service parts and service kits visit www grundfos com select country select WebCAPS 30 Technical data th...

Страница 41: ...contact load 5 VDC 10 mA Screened cable 0 5 2 5 mm2 28 12 AWG Maximum cable length 1640 ft 500 m Bus input Grundfos bus protocol GENIbus protocol RS 485 Screened 3 core cable 28 16 AWG 0 2 1 5 mm2 Ma...

Страница 42: ...for both the first and second environment 5 7 5 10 15 20 25 30 Emission The motors are category C3 corresponding to CISPR11 group 2 class A and may be installed in industrial areas second environment...

Страница 43: ...aker must be of the Inverse time type The interrupting rating RMS symmetrical amperes must not be less than the values stated in table below USA hp 32 1 5 Overload protection Degree of overload protec...

Страница 44: ...44...

Страница 45: ...45...

Страница 46: ...46...

Страница 47: ...Grundfos companies Grundfos CBS Inc 902 Koomey Road Brookshire TX 77423 USA Phone 281 994 2700 Toll Free 1 800 955 5847 Fax 1 800 945 4777 www grundfosexpresssuite com...

Страница 48: ...143 0714 ECM 1139229 7KH QDPH UXQGIRV WKH UXQGIRV ORJR DQG be think innovate DUH UHJLVWHUHG WUDGHPDUNV RZQHG E UXQGIRV ROGLQJ 6 RU UXQGIRV 6 HQPDUN OO ULJKWV UHVHUYHG ZRUOGZLGH k RS ULJKW UXQGIRV ROGL...

Отзывы: