3.2.4 Vacuum meter with limit contacts
3.2.5 Vacuum sensors
3.2.6 Measuring transducer
3.2.7 Measurement and Control Electronics Conex
• See operation manual of measuring amplifiers and controller
Conex
®
DIA-2Q or controller Conex
®
DIS-2Q.
3.3 Dimensioned drawing
Fig. 15
Dimensional drawings of gas dosing systems VGS-141, VGS-143 and VGS-145
Measuring
range
-10 to 0 m WS rel.
Limit
contact
outputs
slow-motion contacts S 21 according to DIN
16085 (E)
1st limit contact: break contact (opens when the
specified value is passed clockwise)
2nd limit contact: make contact (closes when the
specified value is passed clockwise)
Permissible
contact load
voltage
ohmic
load
inductive load in case of
alternating current (cos >
0.7)
230 V AC
45 mA
25 mA
110 V AC
90 mA
45 mA
24 V DC
200 mA
-
Measuring range
-1 to 0 bar rel.
Current output
4-20 mA
4 mA equals to -1 bar
20 mA equals to 0 bar
Power supply
24 V DC
Neccessary cable for
current signal
2-wire, shielded, order no. 96687719
(321-130)
Measuring range
1:10
Below a dosing flow of 10 % no precise
measurement is possible. The current
signal 4 mA may probably not be
reached at a dosing flow of 0 %.
Deviation of linearity
< ± 4 % from upper limit of the measuring
range
Current output
4-20 mA
4 mA equals to 0 % dosing flow
20 mA equals to 100 % dosing flow
Power supply
24 V DC
Maximum load
600
Power consumption
> 0.5 W
Degree of protection
IP65
Degree of protection
0 °C to + 60 °C
TM
0
4
0
809
0
908
6
390
450
50
10
00
18
10
76
0 (DN 20
)
73
0 (DN 40
)
10
00
610
375
30
45
505
52,5
52,5
740
60
200
325
325